2022-09-19 - Ordinance 2022-096 - AMENDING TITLE 15.12 OF THE VILLAGE OF BUFFALO GROVE MUNICIPAL CODE (Amendments to 2014 IL Plumbing Code) Underlined = addition
St ik gh= deletion
September 12, 2022
ORDINANCE NO. 2022-096
AN ORDINANCE AMENDING TITLE 15.12 OF THE VILLAGE OF BUFFALO GROVE MUNICIPAL CODE
WHEREAS,the Village of Buffalo Grove is a Home Rule Unit by virtue of the provisions of the
Constitution of the State of Illinois of 1970.
NOW,THEREFORE, BE IT ORDAINED BY THE VILLAGE PRESIDENT AND BOARD OF TRUSTEES OF
THE VILLAGE OF BUFFALO GROVE,COOK AND LAKE COUNTIES, ILLINOIS AND PURSUANT TO ITS HOME
RULE AUTHORITY:
SECTION 1: Chapter 15.12 of the Village of Buffalo Grove Municipal Code is hereby amended to
read as follows:
15.12.010 Adoption by reference.
The Illinois Plumbing Code(77 III.Admin.Code 890)is adopted by reference.
15.12.020 Amendments.
The Illinois Plumbing Code is amended as follows:
Section 890.1135 WATER CONSERVATION CRITERIA.(Add Section 890.1135 to read as follows.)
a) Pursuant to 17 III.Adm. Code 3730.307(c)4)and subject to the Illinois Plumbing Code(77 III.Adm.Code
890)and the Lawn Irrigation Contractor and Lawn Sprinkler System Registration Code(77 III.Adm.
Code 892), be it hereby ordained that in the Village of Buffalo Grove, all new plumbing fixtures and
irrigation controllers installed after the effective date of this ordinance shall bear the WaterSense label
(as designed by the U.S. Environmental Protection Agency WaterSense Program),when such labeled
fixtures are available.
Section 890.1310 MATERIALS.(Amend (b)and(c)to read as follows).
(b) ABOVE-GROUND PIPING WITHIN BUILDINGS.Water piping above ground shall be type M or type L
copper or galvanized iron.
(c) UNDERGROUND PIPING WITHIN BUILDINGS.Water piping below ground or under a concrete slab shall
be type K copper with minimum joints.
Section 890.1340(b) DETERMINATION OF SIZES FOR DRAINAGE SYSTEM. (Amend (4)to read as
follows.)
(4) For all installations other than residential, no portion of the drainage system installed underground or
below a basement or cellar shall be less than four(4) inches in diameter.
Table A APPROVED MATERIALS FOR WATER SERVICE PIPE
The following are deleted:
(1) Acrylonitrite Butadiene Styrene(ABS) Pipe
(4) Chlorinated Polyvinyl Chloride(CPVC)Pipe
(8) Poly Butylene(PB) Pipe Tubing
(9) Polyethylene(PE) Pipe
(10) Polyethylene(PE)Tubing
(11) Polyvinyl Chloride(PVC) Pipe
Table A APPROVED MATERIALS FOR WATER DISTRIBUTION PIPE
The following are deleted:
2) Chlorinated Polyvinyl Chloride(CPVC)Pipe/Tubing
(5) Cross Linked Polyethlene
(6) Poly Butylene(PB) Pipe/Tubing
SECTION 2:This Ordinance shall be in full force and effect from and after its passage, approval and publication.
This Ordinance may be published in pamphlet form.
AYES: 5—Stein, Ottenheimer, Weidenfeld, Smith, Pike
NAPES: 0—None
ABSENT: 1—Johnson
PASSED: September 19, 2022
APPROVED: September 19, 2022
APPROVED:
Beverly Suss ,Village President
ATTEST:
Jant 'rabian,Village Clerk