2010-0295/17/2010 ORDINANCE NO. 2010-29 AN ORDINANCE APPROVING A SPECIAL USE IN THE R-4 DWELLING DISTRICT VILLAGE OF BUFFALO GROVE, COOK AND LAKE COUNTIES, ILLINOIS Buffalo Grove Golf Course 48 Raupp Boulevard T— Mobile Central LLC Proposed telecommunications facility — antenna and tower WHEREAS, the Village of Buffalo Grove is a Home Rule Unit by virtue of the Illinois Constitution of 1970; and, WHEREAS, the real property legally described in EXHIBIT A ( "Property ") attached hereto' is zoned in the R-4 One - Family Dwelling District with a special use for a public golf course and related facilities; and, WHEREAS, the Village of Buffalo Grove is the Owner of the Property; and, WHEREAS, the Owner proposes to enter into a lease with T- Mobile Central LLC, a Delaware limited liability company to construct a communications antenna and tower (120 feet in height) and a ground -level equipment shelter for wireless communications pursuant to the following exhibits: EXHIBIT A Legal Description EXHIBIT B Narrative concerning compliance with special use criteria of Buffalo Grove Zoning Ordinance EXHIBIT C Letter dated May 5, 2010. by Sanjay Jaisingani, RF Engineer, concerning service coverage for area adjacent to proposed site EXHIBIT D Letter dated May 12, 2010 by Matthew J. Butcher, P.E., concerning interference with public safety communication systems N EXHIBIT E RF (radio frequency) Emissions Compliance Report dated May 10, 2010 by David Charles Cotton, Jr., Licensed Professional Engineer EXHIBIT F Maps of existing service coverage and coverage areas for proposed tower EXHIBIT G Photo simulations of proposed tower at view locations adjacent to site EXBHIT H Site plan, elevations and plat of survey (6 sheets, including LS -1 and LS -2 dated 9/24/2008; and T -1, A -1, A -2 and A -3) dated 4/23/2010 by W -T Communication Design Group, LLC WHEREAS, Insite Real Estate Inc., as agent for T— Mobile Central LLC, a Delaware limited.' liability company, has submitted a petition requesting approval of a special use for -z telecommunications facility including a tower, antenna and equipment shelter pursuant to the provisions and requirements of Chapter 17.34 of the Village Zoning Ordinance; and, , WHEREAS, notice of the public hearing conc'e'rning the petition for the special'use was'giGeri . and the public hearing was held by the Buffalo Grove Plan Commission on April 7,20.l0,-,,and',,.-'.,,1.., WHEREAS, `the Plan 'Cominission determined, pursuant to findings based on the testimony,, presented at the public hearing, that the criteria for a Special Use as set forth in Section 1728,040 of the Village's Zoning 'Ordinance have been met and`the special use is an appropriate use `'of the r Property and will not unduly affect adjacent properties; "and,' WHEREAS, the Corporate Authorities of the Village do hereby find that the proposed cellular communications antenna and tower meet the special use criteria as set forth in Section 17.28.040 of the Buffalo Grove Municipal Code and will comply with the provisions and requirements set forth in Chapter 17.34 of the Village Zoning Ordinance, and specifically make the following findings and conclusions regarding the proposed cellular communications antenna and tower ("telecommunications facility"): 1. It has been demonstrated that coverage for T— Mobile's wireless service in the area of the proposed' telecommunications facility would be improved by construction of the proposed tower and antenna thereby allowing greater cellular telephone use serving the public convenience not only at the location of the installation but throughout the projected coverage area, and the establishment, maintenance and operation of the telecommunications facility will not be detrimental to or endanger the public health, safety, morals, comfort, or general welfare. 2. The nature and intensity of the proposed facility will be in harmony with the appropriate and orderly development of the district in which it is located. 41 3. The distances to the nearest residences, the location of the site, and the open golf course area adjacent to the site indicate that there will not be detrimental effects or injury to the use and enjoyment of other property in the immediate vicinity of the subject property, nor will such use substantially diminish and impair other property valuations within the neighborhood. 4. The nature, location and size of the telecommunications facility will not impede, substantially hinder or discourage the development and use of adjacent land and buildings. 5. Utilities necessary to serve the telecommunications facility are adjacent to the site; there is adequate. access to the site from the adjacent "existing parking lot and street; the proposed- improvements. will not have any significant• impact upon drainage in the area; and any necessary, facilities for the special use have beeti� or Will be •Provided. . , -. 6. The,telecommunications facility will require,maintenance visits only several times ,a year, and the. facility can be served by existing parking, and .paved, access:. Said access is located so that there will not be traffic congestion or hazards adjacent to the site or in'the public streets. 7. The special use in all other respects conforms to the applicable regulations of the R-4 zoning+ ;. district? except as such regulations are varied in this. Ordinance , . NOVA,IEREFORE, BE IT ORDAINED BY THE PRESIDENT AND BOARD OF" . TRUSTEES OF THE VILLAGE OF BUFFALO GROVE, COOK AND LAKE COUNTIES; IT,LINOIS ,. Sectional... This ordinance is made pursuant to`and:inaccordance with the Village's . Zoning Ordinance and the Village's Home Rule powers. The preceding whereas clauses are hereby made a part of this Ordinance. Section 2. The Corporate Authorities hereby approve an amendment to the Special Use for the Property legally described in EXHIBIT A attached hereto. Section 3. The special use is subject to the following: A. The following variation of the Village Zoning Ordinance is hereby granted: Section 17.40.020.B. — to allow a tower height of 120 feet instead of the standard building height of 35 feet in the R-4 District; B. The following variation of the Village Fence Code is hereby granted: Section 15.20.040 — to allow fencing 8 feet in height to screen the ground — level equipment shelter area, and the garbage dumpster area serving the restaurant and clubhouse building. rd C. The appearance and materials for the fences and gates depicted on Exhibit H (site plan and elevations) hereto are subject to review and approval by the Village. D. A final landscaping plan shall be submitted to the Village Forester for review and approval prior to removal of trees, site preparation work or grading on the Property. PASSED: Mgy 17, 2010 APPROVED: ' MgI 17, 2010 ATTEST: illage Clerk This document was prepared by: APPROVED: L ART , Village President Robert E. Pfeil, Village Planner and William G. Raysa, Village Attorney Village of Buffalo Grove 50 Raupp Boulevard Buffalo Grove, IL 60089 611 EXHIBIT A Legal Description T— Mobile telecommunications facility Buffalo Grove Golf Course :48 Rautpp :Boulevard SUBJECT PROPERTY LEGAL DESCRIPTION: THAT :PART OF VILLAGE CAIVIPUSti,SUBDIVISION BEING A SUBDIVISION IN THE SOUTHEAST QUARTER OF SECTION 32 TOWNSHIP 42 NORTH, RANGE 11 EAST OF THE THIRD PRINCIPAL MERIDIAN IN LAKE COUNTY AND IN THE NORTHEAST QUARTER OF SECTION 5, TOWNSHIP ,42 NORTH, .RANGE 11 EAST OF THE THIRD PRINCIPAL' MERIDIAN: COMMENCING AT THE SOUTHWEST CORNER OF SAID VILLAGE CAMPUS- SUBDIVISION; THENCE, NORTH 34 DEGRESS 20 MINUTES 09 SECONDS WEST ALONG THE 'WESTERLY LINE OF SAID SUBDIVISION, 262.3 5, FEET; THENCE NORTH 55 DEGREES 40 MINUTES 02 SECONDS EAST; 246:85 FEET TO THE POINT BEGINNING;` THENCE CONTINUING NORTH 55 DEGREES 40 MINUTES 02 SECONDS EAST, 25.67 FEET-'': THENCE SOUTH 34 DEGREES.' 19, MINUTES 58 SECONDS EAST, 13.00 FEET; THENCE SOUTH 55 DEGREES 40 MINUTES 02 SECONDS WEST, 25.67 FEET; THENCE NORTH'34 DEGREES 19 MINUTES 58 SECONDS WEST, 13.00 FEET TO THE POINT OF BEGINNING, CONTAINING 334.00 SQUARE FEET, MORE OR LESS, ALL IN COOK COUNTY, ILLINOIS. Aft „ 'cow-, ------ _. ..W, T- MOBILE WIRELESS COMMUNICATIONS FACILITY BUFFALO GROVE GOLF COURSE Petitioner T- Mobile is a leading national wireless phone carrier and offers one of the finest wireless communications networks in the nation. T- Mobile has entered into a lease agreement with the Buffalo Grove Golf Course (owner) to install a wireless communications facility at the Course located at 48 Raupp Boulevard. Property Description The Buffalo Grove Golf Course is located at 48 Raupp Road in the Village of Buffalo Grove. The Golf Course is located on municipally owned property. T- Mobile proposes to install a 120' stealth flag pole with (6) antennas inside the pole and related equipment at grade level adjacent to the pole. The facility will be located on a (13' -0" x 25' -0 ") lease area which will be surrounded by a cedar fence. Access to the proposed facility will be via a new access easement on the existing parking lot and driveway off of Raupp Boulevard. The proposed facility is located in the R -4 Zoning District. Nature of Request/Zoning Analysis T- Mobile seeks a Special Use Permit and any other permits necessary to allow the installation of its proposed wireless antenna facility. Nature of Request /Zoning Analysis T- Mobile seeks a Special Use permit (pursuant to the Table of Regulations below) and any other permits necessary to allow the installation of its proposed wireless antenna facility at the Buffalo Grove Golf Course. Section 17.40.020 A. Table of Use Regulations (R -E through R -6A one family dwelling districts) of the Buffalo Grove Zoning Ordinance states in relevant part: Special Uses Personal wireless communications facilities and cellular telephone facilities, including antennas, for use with radio and /or other transmitting and receiving equipment, on a tower or pole, on property owned by a unit of local government or a public utility. Said tower or pole shall be set back from non - residential property lines a distance not less than the height of the tower or pole. Said tower or pole shall be setback from a residential structure and any abutting residential zoning boundary a distance not less than twice the height of the tower or pole. Components and Operations The proposed facility will be unstaffed and, upon completion, will require only infrequent maintenance visits (approximately one or two times a month) by a service technician. Access to the proposed facility will be via a new access easement on the parking lot and driveway off of Raupp Boulevard. Hence, the facility will not have any material impact on traffic, parking or storm water control. The proposed facility is entirely self - monitored by sophisticated computers which connect directly to a central office and which alert personnel to equipment malfunction or breach of security. Moreover, no material noise, glare, smoke, debris, traffic flow or any other nuisance will be generated by the proposed facility. The proposed facility will be designed and constructed to meet applicable governmental and industry safety standards. Specifically, T- Mobile will comply with FCC and FAA rules governing construction requirements, technical standards, interference protection, power and height limitations and radio frequency standards. Requested Action T- Mobile respectfully requests a Special Use Permit and any other relief necessary to accommodate the installation of a wireless antenna facility at the Buffalo Grove Golf Course located at 48 Raupp Boulevard. T- Mobile expressly reserves all of its rights, including those available to it under the Buffalo Grove Code of Ordinances or any other state, local or federal law. 2 Special Use Criteria A. All special uses shall meet the following criteria: 1. The special use will serve the public convenience at the location of the subject property; or the establishment, maintenance or operation of the special use will not be detrimental to or endanger the public health, safety, morals, comfort, or general welfare; The special use will serve the public convenience at the location of the subject property and the establishment, maintenance or operation of the special use will not be detrimental to or endanger the public health, safety, morals, comfort, or general welfare; To the contrary, reliable wireless technology provides vital communications that will be commonly used by local residents, businesses, and emergency personnel for a wide variety of communication needs thereby promoting the general public's health, safety, morals, comfort and overall general welfare. Utility networks such as electric, gas, water, and wireless networks are essential to the development of any community. Wireless communications are not a luxury anymore; they have become part of our lifestyle. Over 75 percent of all US households use a wireless phone or data device and its projected that there will be more than 60 million new subscribers in the next five years. Every day, wireless phone users place over 200,000 calls a day to 9 -1 -1 and other emergency numbers to save lives and assist victims in accidents, crimes, fires, storms and natural disasters. The increased use as resulted in a new caller location system called "Enhanced 911" (E911). This system ensures that a wireless call is routed to the nearest emergency dispatch center. It also provides emergency dispatchers with a call -back number of the distressed call and provides the approximate location of the distressed caller. By improving the quality of the wireless infrastructure, the proposed special use will provide improved wireless service to the Golf Club itself and hence serve the public convenience at the golf club and beyond. 2. The location and size of the special use, the nature and intensity of the operation involved in or conducted in connection with said special use, the size of the subject property in relation to such special use, and the location of the site with respect to streets giving access to it shall be such that it will be in harmony with the appropriate, orderly development of the district in which it is located; As depicted in the site plan, the proposed facility is diminutive in size in relation to the size of the Buffalo Grove Golf Course. The lease area is (13' -0" x 25 -0 ") and will be enclosed by a cedar fence. The lease area will be appropriately landscaped to blend in with the immediate vicinity. Typically, once a site is built and operational, it is visited by a technician for routine system checks once or twice monthly during normal business hours. There will be no traffic congestion that will result from such visits. Access to the site will be via a new 20' wide access easement on the existing parking lot and driveway off of Raupp Boulevard. For these reasons, the location, size, nature and intensity of the special use will be in harmony with the appropriate, orderly development of the district in which it is located. 3. The special use will not be injurious to the use and enjoyment of other property in the immediate vicinity of the subject property for the purposes already permitted in such zoning district, nor substantially diminish and impair other property valuations with the neighborhood; T- Mobile has been sensitive in selecting a site and design that will minimize the impact on the surrounding property. The maintenance and operation of the proposed facility will be wholly contained within a (13' -0' x 25' -0 ") lease area. Due to the diminutive size of the lease area and the nature of wireless technology, there will be little impact on the use and enjoyment of the property in the immediate vicinity for the purposes already permitted in the zoning district, nor will there be any adverse effect on property values within the surrounding area. Improved wireless communications will enhance the character of the neighborhood by improving public safety, convenience and efficiency to many residents of the neighborhood. 4. The nature, location and size of the buildings or structures involved with the establishment of the special use will not impede, substantially hinder or discourage the development and use of adjacent land and buildings in accord with the zoning district within which they lie; T- Mobile has been sensitive in selecting and designing the proposed facility so that it does not negatively impact the permitted uses or enjoyment of the properties in the immediate area or impede, hinder or discourage development and use of adjacent land and buildings. The monopole and related equipment will be enclosed by a cedar fence and will be appropriately landscaped to blend in with the immediate vicinity. As stated above, reliable utility networks such as electric, gas, water, and wireless networks are essential to the development of any community. 5. Adequate utilities, access roads, drainage, and/or other necessary facilities have been or will be provided; A wireless facility is unstaffed. The only utilities which will be required are telephone and electricity, both of which are available on site. No drainage, sanitation, refuse removal, parks, library, or school services will be necessary for this facility. This site is entirely self - monitored and connects directly to a central office where sophisticated computers alert personnel to any equipment malfunction or breach of security. Existing police and fire protection are more than adequate to provide for this facility. 6. Parking areas shall be of adequate size for the particular special use, which areas shall be properly located and suitably screened from adjoining residential uses, and the entrance and exit driveways to and from these parking areas shall be designed so as to prevent traffic hazards, eliminate nuisance and minimize traffic congestion in the public streets. A wireless facility is unstaffed and will be visited once or twice monthly by maintenance personnel, and thus, there will be no need for any additional parking spaces in the existing, adjacent lot to accommodate these visits. With just a couple visits each month, there will be no traffic hazards nor any other nuisances to traffic patterns nor any adverse affect on traffic congestion in the public streets. Access to the site will be via a new 20' wide access easement on the existing parking lot and driveway off of Raupp Boulevard. B. The special use shall in all other respects conform to the applicable regulations of the zoning district in which it is located, except as such regulations may be varied. The special use shall in all other respects conform to the applicable regulations of the R4 Zoning District, except as such regulations may be varied. SON 1. 0 -Mobile May 5, 2010 To Whom It May Concern: T- Mobile has classified different levels of signal strength to adequately serve varying grades of users. In short T- mobile has categorized signal level into 3 different categories to enable it to design its network and thus provide the desired coverage with a high degree of confidence. The different signal levels correspond to different colors on a propagation map and are defined as follows: Green: -76 dBm < = Signal Level. Level required for In- Building coverage Yellow: -84dBm < = Signal Level < - 76d.Bm. Level required for In- Vehicle coverage Light Grey: -91 dBm < = Signal Level < - 84dBm. Level required for Outdoor coverage T- Mobile's current coverage in the village of Buffalo Grove based on the aforementioned thresholds and propagation maps supplied to the village can be qualified as reliable In- Vehicle coverage. The purpose of this site is to improve the gaps in residential coverage that exist along Lake Cook Rd. between Buffalo Grove Rd and Arlington Height Rd as well in the residential area South of Lake Cook Rd. The proposed communication tower at 50 Raupp Blvd. in Buffalo Grove will greatly help in achieving the coverage objective. T- Mobile USA, Inc. — Chicago . s i te, r compliance experts May 12, 2010 Insite, Incorporated Attn: Mike Howley 2210 Midwest Road Suite 213 Oak Brook, IL 60523 200 North h Glebe Road, Suite 10 Adi Arlington, VA 22203 -3728 ' Ad- Re: T- Mobile Potential Interference with Village of Buffalo Grove Public Safety Systems Dear Mr. Howley: Based on the information you provided, T- Mobile intends to operate their equipment at the site located at 48 Raupp Boulevard, Buffalo Grove, IL 60089 on the basis of FCC licenses which exclusively entitles the company to operate within an assigned frequency range of 1970 -1990 and 2110 -2120 MHz. Their operating frequencies preclude the potential of interference issues with Village of Buffalo Grove public safety services located at a tower in proximity of the proposed location. I have received and reviewed the city's Antenna Coax Color Code Chan` regarding what is on the village hall tower. Based upon the information provided, I conclude that there will be no interference. In the unlikely event that interference is created, T- Mobile, as a condition of their FCC licenses, assumes full responsibility to take necessary measures to resolve these issues. Please feel free to contact me at any time if additional information or clarification on power levels or interference issues is needed. Sincerely, Matthew J Butcher, PE Commonwealth of Virginia License Number 40784 VP, Engineering and Development Site Safe, Inc 200 N Glebe Rd, Suite 1000 Arlington, VA 22203 (703) 558 -0502 matt - sitesafe.com Sitesafe, Inc. 1 703.276.1100 1 703.276.1169 fax I www.sitesafe.com MA1iHEW J gOSCHER v L4C. No. 407$4 G��'SS1(3N R1- �Cyu ~ _ O SIM= V4 �,:�...... , :: .. :.: ..:. :::..:X.: ,.- -5- RF EMISSIONS COMPLIANCE REPORT T- Mobile Site: CH33 -259H - Buffalo Grove Golf Course 50 Raupp Boulevard Buffalo Grove, IL 5/10/2010 Report Status: Prepared By: Sitesafe, Inc. 200 North Glebe Road, Suite 1000 Arlington, VA 22203 Voice 703 - 276 -1100 Fax 703 - 276 -1169 David Charles Cotton, Jr. Licensed Professional Engineer State of Colorado, PE -41914 Date: 2010 - May -10 Engineering Statement in Re: Electromagnetic Energy Analysis T- Mobile Buffalo Grove, IL My signature on the cover of this document indicates: That I am registered as a Professional Engineer in the jurisdiction indicated; and That I have extensive professional experience in the wireless communications engineering industry; and That I am an employee of Sitesafe, Inc. in Arlington, Virginia; and That I am thoroughly familiar with the Rules and Regulations of the Federal Communications Commission ( "the FCC" and "the FCC Rules ") both in general and specifically as they apply to the FCC's Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields; and That the technical information serving as the basis for this report was supplied by T- Mobile (See attached Site Summary and Carrier documents), and that T- Mobile's installations involve communications equipment, antennas and associated technical equipment at a location referred to as the "CH33 -259H - Buffalo Grove Golf Course" ("the site "); and That T- Mobile proposes to operate at the site with transmit antennas listed in the carrier summary and with a maximum effective radiated power as specified by T- Mobile and shown on the worksheet, and that worst -case 100% duty cycle have been assumed; and That this analysis has been performed with the assumption that the ground immediately surrounding the tower is primarily flat or falling; and That at this time, the FCC requires that certain licensees address specific levels of radio - frequency energy to which workers or members of the public might possibly be exposed (at § 1.1307(b) of the FCC Rules); and That such consideration of possible exposure of humans to radio- frequency radiation must utilize the standards set by the FCC, which is the Federal Agency having jurisdiction over communications facilities; and That the FCC rules define two tiers of permissible exposure guidelines: 1) "uncontrolled environments," defined as situations in which persons may not be aware of (the "general public "), or may not be able to control their exposure to a transmission facility; and (2) "controlled environments," which defines situations in which persons are aware of their potential for exposure (industry personnel); and That this statement specifically addresses the uncontrolled environment (which is more conservative than the controlled environment) and the limit set forth in the FCC rules for licensees of T- Mobile's operating frequency as shown on the attached antenna worksheet; and That when applying the uncontrolled environment standards, the predicted Maximum Power Density at two meters above ground level from the proposed T- Mobile operation is no more than 0.236% of the maximum in any accessible area on the ground and 1 of 13 I rp That it is understood per FCC Guidelines and OET65 Appendix A, that regardless of the existent radio - frequency environment, only those licenses whose contributions exceed five percent of the exposure limit pertinent to their operation(s) bear any responsibility for bringing any non- compliant area(s) into compliance; and That the calculations provided in this report are based on data provided by the client and antenna pattern data supplied by the antenna manufacturer, in accordance with FCC guidelines listed in OET -65. Horizontal and vertical antenna patterns are combined for modeling purposes to accurately reflect the energy two meters above ground level where on -axis energy refers to maximum energy two meters above the ground along the azimuth of the antenna and where area energy refers to the maximum energy anywhere two meters above the ground regardless of the antenna azimuth, accounting for cumulative energy from multiple antennas for the carrier and frequency range indicated; and That the Occupational Safety and Health Administration has policies in place which address worker safety in and around communications sites, thus individual companies will be responsible for their employees' training regarding Radio Frequency Safety. In summary, it is stated here that the proposed operation at the site would not result in exposure of the Public to excessive levels of radio - frequency energy as defined in the FCC Rules and Regulations, specifically 47 CFR 1.1307 and that T- Mobile's proposed operation is completely compliant. Finally, it is stated that access to the tower should be restricted to communication industry professionals, and approved contractor personnel trained in radio- frequency safety; and that the instant analysis addresses exposure levels at two meters above ground level and does not address exposure levels on the tower, or in the immediate proximity of the antennas. 2of13 5e T-Mobile CH33-259H - Buffalo Grove Golf Course Site Summary Carrier Area Maximum Percentage MPE T-Mobile 0.236% Composite Site MPE: 0.236% 3 of 13 4of13 SIB T- Mobile • CH33 -259H - Buffalo Grove Golf Course Carrier Summary Frequency: 1975.4 MHz Maximum Permissible Exposure (MPE): 1000 NW /cm ^2 Maximum power density at ground level: 2.36067 NW /cm ^2 Highest percentage of Maximum Permissible Exposure: 0.23607 % On Axis Area Max Power Max Power Height Orientation ERP Density Percent of Density Percent of Antenna Make Model feet (degrees true (Watts) W /cm ^2 MPE W /cm ^2 MPE Andrew TMBX- 6516 -R2M 120 0 879 0.33576 0.033576 0.693401 0.06934 Andrew TMBX- 6516 -R2M 120 0 878 0.335378 0:033538 0.692612 0.069261 Andrew TMBX- 6516 -R2M 120 0 878 0.335378 0.033538 0.692612 0.069261 Andrew TMBX- 6516 -R2M 120 110 879 0.33576 0.033576 0.6934 0.06934 Andrew TMBX- 6516 -R2M 120 110 878 0.335378 0.033538 0.692612 0.069261 Andrew TMBX- 6516 -R2M 120 110 878 0.335378 0.033538 0.692612 0.069261 Andrew TMBX - 6516 -R2M 120 240 879 0.33576 0.033576 0.6934 0.06934 Andrew TMBX- 6516 -R2M 120 240 878 0.335378 0.033538 0.692612 0.069261 Andrew TMBX- 6516 -R2M 120 240 878 0.335378 0.033538 0.692612 0.069261 4of13 SIB T- Mobile CH33 -259H - Buffalo Grove Golf Course Andrew:TMBX- 6516 -R2M Antenna Worksheet (0 Sector) Maximum Permissible Exposure (MPE): 1000 Height Frequency Downtilt ERP (Watts): 879 (feet): 120 (MHz): 1975 (Degrees): 0.0 Depression Slant Dist From Angle Relative Distance Structure Power Density Percent of Times (degrees) Relative dB Gain (meters) (meters) (NW /cm ^2) MPE Below MPE 0.1 0.00 1.0000 19810.64 19810.61 0.000075 0.000007 13390056 1.0 0.00 1.0000 1981.16 1980.86 0.007467 0.000747 133914 2.0 -0.50 0.8913 990.73 990.13 0.029861 0.002986 33488 3.0 -1.60 0.6918 660.66 659.75 0.067153 0.006715 14891 4.0 -3.20 0.4786 495.67 494.46 0.119298 0.011930 8382 5.0 -5.50 0.2818 396.72 39521 0.186232 0.018623 5369 6.0 -8.90 0.1288 330.78 328.97 0.267875 0.026788 3733 7.0 -13.90 0.0407 283.71 281.60 0.326744 0.032674 3060 8.0 -25.00 0.0032 248.44 246.02 0.335760 0.033576 2978 9.0 -27.00 0.0020 221.03 218.30 0.299558 0.029956 3338 10.0 -18.40 0.0145 199.12 196.09 0.224251 0.022425 4459 12.0 -16.60 0.0219 166.30 162.67 0.052018 0.005202 19224 14.0 -22.70 0.0054 142.92 138.68 0.040861 0.004086 24473 16.0 -30.40 0.0009 125.44 120.58 0.052964 0.005296 18880 18.0 -21.00 0.0079 111.89 106.41 0.041210 0.004121 24265 20.0 -22.00 0.0063 101.09 95.00 0.031974 0.003197 31275 22.0 -30.90 0.0008 92.30 85.58 0.038244 0.003824 26147 24.0 -30.70 0.0009 85.01 77.66 0.044953 0.004495 22245 26.0 -26.80 0.0021 78.87 70.89 0.020057 0.002006 49858 28.0 -34.90 0.0003 73.65 65.03 0.080642 0.008064 12400 30.0 -27.30 0.0019 69.15 59.89 0.174777 0.017478 5721 32.0 -19.30 0.0117 65.25 55.33 0.213477 0.021348 4684 34.0 -16.30 0.0234 61.83 51.26 0.236710 0.023671 4224 36.0 -15.90 0.0257 58.82 47.59 0.260759 0.026076 3834 38.0 -17.60 0.0174 56.16 44.26 0.284863 0.028486 3510 40.0 -21.50 0.0071 53.79 41.21 0.309196 0.030920 3234 42.0 -28.50 0.0014 51.67 38.40 0.292901 0.029290 3414 44.0 -40.00 0.0001 49.77 35.80 0.174720 0.017472 5723 46.0 -36.50 0.0002 48.07 33.39 0.061584 0.006158 16238 48.0 -35.50 0.0003 46.53 31.13 0.007304 0.000730 136903 50.0 -40.00 0.0001 45.14 29.01 0.007705 0.000770 129793 52.0 -40.00 0.0001 43.88 27.01 0.013352 0.001335 74892 54.0 -34.40 0.0004 42.74 25.12 0.014931 0.001493 66973 56.0 -32.10 0.0006 41.71 23.32 0.015566 0.001557 64241 58.0 -32.10 0.0006 40.77 21.61 0.016171 0.001617 61838 60.0 -33.80 0.0004 39.93 19.96 0.016764 0.001676 59650 62.0 -36.60 0.0002 39.16 18.38 0.017301 0.001730 57798 64.0 -39.90 0.0001 38.47 16.86 0.014324 0.001432 69812 66.0 -39.60 0.0001 37.85 15.39 0.017483 0.001748 57198 68.0 -35.20 0.0003 37.29 13.97 0.025319 0.002532 39496 70.0 -32.00 0.0006 36.80 12.58 0.027531 0.002753 36323 72.0 -30.40 0.0009 36.36 11.23 0.028006 0.002801 35707 74.0 -30.10 0.0010 35.97 9.91 0.028414 0.002841 35194 76.0 -31.10 0.0008 35.63 8.62 0.028716 0.002872 34823 78.0 -33.20 0.0005 35.35 7.35 0.028986 0.002899 34499 80.0 -36.40 0.0002 35.11 6.10 0.027307 0.002731 36620 82.0 -40.00 0.0001 34.92 4.86 0.019768 0.001977 50585 84.0 -40.00 0.0001 34.77 3.63 0.010774 0.001077 92813 86.0 -40.00 0.0001 34.66 2.42 0.004701 0.000470 212717 88.0 -40.00 0.0001 34.60 1.21 0.004386 0.000439 228000 90.0 -39.20 0.0001 34.58 0.00 0.004358 0.000436 229488 5of13 sit.(e T- Mobile CH33 -259H - Buffalo Grove Golf Course Andrew:TMBX- 6516 -R2M Antenna Worksheet (0 Sector) Maximum Permissible Exposure (MPE): 1000 Height Frequency Downtilt ERP (Watts): 878 (feet): 120 (MHz): 1975 (Degrees): 0.0 Depression Slant Dist From Angle Relative Distance Structure Power Density Percent of Times (degrees) Relative dB Gain (meters) (meters) (NW /cm ^2) MPE Below MPE 0.1 0.00 1.0000 19810.64 19810.61 0.000075 0.000007 13405308 1.0 0.00 1.0000 1981.16 1980.86 0.007459 0.000746 134066 2.0 -0.50 0.8913 990.73 990.13 0.029827 0.002983 33526 3.0 -1.60 0.6918 660.66 659.75 0.067076 0.006708 14908 4.0 -3.20 0.4786 495.67 494.46 0.119162 0.011916 8391 5.0 -5.50 0.2818 396.72 395.21 0.186021 0.018602 5375 6.0 -8.90 0.1288 330.78 328.97 0.267570 0.026757 3737 7.0 -13.90 0.0407 283.71 281.60 0.326372 0.032637 3063 8.0 -25.00 0.0032 248.44 246.02 0.335378 0.033538 2981 9.0 -27.00 0.0020 221.03 218.30 0.299217 0.029922 3342 10.0 -18.40 0.0145 199.12 196.09 0.223996 0.022400 4464 12.0 -16.60 0.0219 166.30 162.67 0.051959 0.005196 19246 14.0 -22.70 0.0054 142.92 138.68 0.040814 0.004081 24501 16.0 -30.40 0.0009 125.44 120.58 0.052904 0.005290 18902 18.0 -21.00 0.0079 111.89 106.41 0.041163 0.004116 24293 20.0 -22.00 0.0063 101.09 95.00 0.031937 0.003194 31311 22.0 -30.90 0.0008 92.30 85.58 0.038201 0.003820 26177 24.0 -30.70 0.0009 85.01 77.66 0.044902 0.004490 22270 26.0 -26.80 0.0021 78.87 70.89 0.020034 0.002003 49915 28.0 -34.90 0.0003 73.65 65.03 0.080550 0.008055 12414 30.0 -27.30 0.0019 69.15 59.89 0.174578 0.017458 5728 32.0 -19.30 0.0117 65.25 55.33 0.213235 0.021323 4689 34.0 -16.30 0.0234 61.83 51.26 0.236441 0.023644 4229 36.0 -15.90 0.0257 58.82 47.59 0.260462 0.026046 3839 38.0 -17.60 0.0174 56.16 44.26 0.284539 0.028454 3514 40.0 -21.50 0.0071 53.79 41.21 0.308844 0.030884 3237 42.0 -28.50 0.0014 51.67 38.40 0.292568 0.029257 3418 44.0 -40.00 0.0001 49.77 35.80 0.174521 0.017452 5729 46.0 -36.50 0.0002 48.07 33.39 0.061514 0.006151 16256 48.0 -35.50 0.0003 46.53 31.13 0.007296 0.000730 137059 50.0 -40.00 0.0001 45.14 29.01 0.007696 0.000770 129940 52.0 -40.00 0.0001 43.88 27.01 0.013337 0.001334 74978 54.0 -34.40 0.0004 42.74 25.12 0.014914 0.001491 67049 56.0 -32.10 0.0006 41.71 23.32 0.015549 0.001555 64314 58.0 -32.10 0.0006 40.77 21.61 0.016153 0.001615 61908 60.0 -33.80 0.0004 39.93 19.96 0.016745 0.001675 59718 62.0 -36.60 0.0002 39.16 18.38 0.017282 0.001728 57864 64.0 -39.90 0.0001 38.47 16.86 0.014308 0.001431 69892 66.0 -39.60 0.0001 37.85 15.39 0.017463 0.001746 57263 68.0 -35.20 0.0003 37.29 13.97 0.025290 0.002529 39541 70.0 -32.00 0.0006 36.80 12.58 0.027499 0.002750 36364 72.0 -30.40 0.0009 36.36 11.23 0.027974 0.002797 35747 74.0 -30.10 0.0010 35.97 9.91 0.028381 0.002838 35234 76.0 -31.10 0.0008 35.63 8.62 0.028684 0.002868 34862 78.0 -33.20 0.0005 35.35 7.35 0.028953 0.002895 34538 80.0 -36.40 0.0002 35.11 6.10 0.027276 0.002728 36662 82.0 -40.00 0.0001 34.92 4.86 0.019746 0.001975 50643 84.0 -40.00 0.0001 34.77 3.63 0.010762 0.001076 92919 86.0 -40.00 0.0001 34.66 2.42 0.004696 0.000470 212959 88.0 -40.00 0.0001 34.60 1.21 0.004381 0.000438 228259 90.0 -39.20 0.0001 34.58 0.00 0.004353 0.000435 229749 6of13 site _ T- Mobile CH33 -259H - Buffalo Grove Golf Course Andrew:TMBX- 6516 -R2M Antenna Worksheet (0 Sector) Maximum Permissible Exposure (MPE): 1000 Height Frequency Downtilt ERP (Watts): 878 (feet): 120 (MHz): 1975 (Degrees): 0.0 Depression Slant Dist From Angle Relative Distance Structure Power Density Percent of Times (degrees) Relative dB Gain (meters) (meters) (NW /cm"2) MPE Below MPE 0.1 0.00 1.0000 19810.64 19810.61 0.000075 0.000007 13405308 1.0 0.00 1.0000 1981.16 1980.86 0.007459 0.000746 134066 2.0 -0.50 0.8913 990.73 990.13 0.029827 0.002983 33526 3.0 -1.60 0.6918 660.66 659.75 0.067076 0.006708 14908 4.0 -3.20 0.4786 495.67 494.46 0.119162 0.011916 8391 5.0 -5.50 0.2818 396.72 395.21 0.186021 0.018602 5375 6.0 -8.90 0.1288 330.78 328.97 0.267570 0.026757 3737 7.0 -13.90 0.0407 283.71 281.60 0.326372 0.032637 3063 8.0 -25.00 0.0032 248.44 246.02 0.335378 0.033538 2981 9.0 -27.00 0.0020 221.03 218.30 0.299217 0.029922 3342 10.0 -18.40 0.0145 199.12 196.09 0.223996 0.022400 4464 12.0 -16.60 0.0219 166.30 162.67 0.051959 0.005196 19246 14.0 -22.70 0.0054 142.92 138.68 0.040814 0.004081 24501 16.0 -30.40 0.0009 125.44 120.58 0.052904 0.005290 18902 18.0 -21.00 0.0079 111.89 106.41 0.041163 0.004116 24293 20.0 -22.00 0.0063 101.09 95.00 0.031937 0.003194 31311 22.0 -30.90 0.0008 92.30 85.58 0.038201 0.003820 26177 24.0 -30.70 0.0009 85.01 77.66 0.044902 0.004490 22270 26.0 -26.80 0.0021 78.87 70.89 0.020034 0.002003 49915 28.0 -34.90 0.0003 73.65 65.03 0.080550 0.008055 12414 30.0 -27.30 0.0019 69.15 59.89 0.174578 0.017458 5728 32.0 -19.30 0.0117 65.25 55.33 0.213235 0.021323 4689 34.0 -16.30 0.0234 61.83 51.26 0.236441 0.023644 4229 36.0 -15.90 0.0257 58.82 47.59 0.260462 0.026046 3839 38.0 -17.60 0.0174 56.16 44.26 0.284539 0.028454 3514 40.0 -21.50 0.0071 53.79 41.21 0.308844 0.030884 3237 42.0 -28.50 0.0014 51.67 38.40 0.292568 0.029257 3418 44.0 -40.00 0.0001 49.77 35.80 0.174521 0.017452 5729 46.0 -36.50 0.0002 48.07 33.39 0.061514 0.006151 16256 48.0 -35.50 0.0003 46.53 31.13 0.007296 0.000730 137059 50.0 -40.00 0.0001 45.14 29.01 0.007696 0.000770 129940 52.0 -40.00 0.0001 43.88 27.01 0.013337 0.001334 74978 54.0 -34.40 0.0004 42.74 25.12 0.014914 0.001491 67049 56.0 -32.10 0.0006 41.71 23.32 0.015549 0.001555 64314 58.0 -32.10 0.0006 40.77 21.61 0.016153 0.001615 61908 60.0 -33.80 0.0004 39.93 19.96 0.016745 0.001675 59718 62.0 -36.60 0.0002 39.16 18.38 0.017282 0.001728 57864 64.0 -39.90 0.0001 38.47 16.86 0.014308 0.001431 69892 66.0 -39.60 0.0001 37.85 15.39 0.017463 0.001746 57263 68.0 -35.20 0.0003 37.29 13.97 0.025290 0.002529 39541 70.0 -32.00 0.0006 36.80 12.58 0.027499 0.002750 36364 72.0 -30.40 0.0009 36.36 11.23 0.027974 0.002797 35747 74.0 -30.10 0.0010 35.97 9.91 0.028381 0.002838 35234 76.0 -31.10 0.0008 35.63 8.62 0.028684 0.002868 34862 78.0 -33.20 0.0005 35.35 7.35 0.028953 0.002895 34538 80.0 -36.40 0.0002 35.11 6.10 0.027276 0.002728 36662 82.0 -40.00 0.0001 34.92 4.86 0.019746 0.001975 50643 84.0 -40.00 0.0001 34.77 3.63 0.010762 0.001076 92919 86.0 -40.00 0.0001 34.66 2.42 0.004696 0.000470 212959 88.0 -40.00 0.0001 34.60 1.21 0.004381 0.000438 228259 90.0 -39.20 0.0001 34.58 0.00 0.004353 0.000435 229749 7 of 13 m r. se eir xs3�i'u is cc��irp?r >s T- Mobile 8of13 CH33 -259H - Buffalo Grove Golf Course Andrew:TMBX- 6516 -R2M Antenna Worksheet (110 Sector) Maximum Permissible Exposure (MPE): 1000 Height Frequency Downtilt ERP (Watts): 879 (feet): 120 (MHz): 1975 (Degrees): 0.0 Depression Slant Dist From Angle Relative Distance Structure Power Density Percent of Times (degrees) Relative dB Gain (meters) (meters) (pWlcm ^2) MPE Below MPE 0.1 0.00 1.0000 19810.64 19810.61 0.000075 0.000007 13390054 1.0 0.00 1.0000 1981.16 1980.86 0.007467 0.000747 133914 2.0 -0.50 0.8913 990.73 990.13 0.029861 0.002986 33488 3.0 -1.60 0.6918 660.66 659.75 0.067153 0.006715 14891 4.0 -3.20 0.4786 495.67 494.46 0.119298 0.011930 8382 5.0 -5.50 0.2818 396.72 395.21 0.186232 0.018623 5369 6.0 -8.90 0.1288 330.78 328.97 0.267875 0.026788 3733 7.0 -13.90 0.0407 283.71 281.60 0.326744 0.032674 3060 8.0 -25.00 0.0032 248.44 246.02 0.335760 0.033576 2978 9.0 -27.00 0.0020 221.03 218.30 0.299558 0.029956 3338 10.0 -18.40 0.0145 199.12 196.09 0.224251 0.022425 4459 12.0 -16.60 0.0219 166.30 162.67 0.052018 0.005202 19224 14.0 -22.70 0.0054 142.92 138.68 0.040861 0.004086 24473 16.0 -30.40 0.0009 125.44 120.58 0.053167 0.005317 18808 18.0 -21.00 0.0079 111.89 106.41 0.041368 0.004137 24173 20.0 -22.00 0.0063 101.09 95.00 0.032055 0.003206 31196 22.0 -30.90 0.0008 92.30 85.58 0.038244 0.003824 26147 24.0 -30.70 0.0009 85.01 77.66 0.045068 0.004507 22188 26.0 -26.80 0.0021 78.87 70.89 0.020108 0.002011 49731 28.0 -34.90 0.0003 73.65 65.03 0.080848 0.008085 12368 30.0 -27.30 0.0019 69.15 59.89 0.174777 0.017478 5721 32.0 -19.30 0.0117 65.25 55.33 0.213477 0.021348 4684 34.0 -16.30 0.0234 61.83 51.26 0.236710 0.023671 4224 36.0 -15.90 0.0257 58.82 47.59 0.260759 0.026076 3834 38.0 -17.60 0.0174 56.16 44.26 0.284863 0.028486 3510 40.0 -21.50 0.0071 53.79 41.21 0.308802 0.030880 3238 42.0 -28.50 0.0014 51.67 38.40 0.292901 0.029290 3414 44.0 -40.00 0.0001 49.77 35.80 0.174275 0.017428 5738 46.0 -36.50 0.0002 48.07 33.39 0.061427 0.006143 16279 48.0 -35.50 0.0003 46.53 31.13 0.007277 0.000728 137428 50.0 -40.00 0.0001 45.14 29.01 0.007685 0.000768 130124 52.0 -40.00 0.0001 43.88 27.01 0.013352 0.001335 74892 54.0 -34.40 0.0004 42.74 25.12 0.014874 0.001487 67229 56.0 -32.10 0.0006 41.71 23.32 0.015566 0.001557 64;11 58.0 -32.10 0.0006 40.77 21.61 0.016171 0.001617 61838 60.0 -33.80 0.0004 39.93 19.96 0.016700 0.001670 59878 62.0 -36.60 0.0002 39.16 18.38 0.017301 0.001730 57798 64.0 -39.90 0.0001 38.47 16.86 0.014324 0.001432 69812 66.0 -39.60 0.0001 37.85 15.39 0.017438 0.001744 57344 68.0 -35.20 0.0003 37.29 13.97 0.025319 0.002532 39496 70.0 -32.00 0.0006 36.80 12.58 0.027531 0.002753 36323 72.0 -30.40 0.0009 36.36 11.23 0.027934 0.002793 35798 74.0 -30.10 0.0010 35.97 9.91 0.028414 0.002841 35194 76.0 -31.10 0.0008 35.63 8.62 0.028643 0.002864 34912 78.0 -33.20 0.0005 35.35 7.35 0.028986 0.002899 34499 80.0 -36.40 0.0002 35.11 6.10 0.027203 0.002720 36760 82.0 -40.00 0.0001 34.92 4.86 0.019693 0.001969 50779 84.0 -40.00 0.0001 34.77 3.63 0.010719 0.001072 93287 86.0 -40.00 0.0001 34.66 2.42 0.004683 0.000468 213532 88.0 -40.00 0.0001 34.60 1.21 0.004386 0.000439 228000 90.0 -39.20 0.0001 34.58 0.00 0.004358 0.000436 229487 8of13 T- Mobile CH33 -259H - Buffalo Grove Golf Course Andrew:TMBX- 6516 -R2M Antenna Worksheet (110 Sector) Maximum Permissible Exposure (MPE): 1000 Height Frequency Downtilt ERP (Watts): 878 (feet): 120 (MHz): 1975 (Degrees): 0.0 Depression Slant Dist From Angle Relative Distance Structure Power Density Percent of Times (degrees) Relative dB Gain (meters) (meters) (NWlcm ^2) MPE Below MPE 0.1 0.00 1.0000 19810.64 19810.61 0.000075 0.000007 13405306 1.0 0.00 1.0000 1981.16 1980.86 0.007459 0.000746 134066 2.0 -0.50 0.8913 990.73 990.13 0.029827 0.002983 33526 3.0 -1.60 0.6918 660.66 659.75 0.067076 0.006708 14908 4.0 -3.20 0.4786 495.67 494.46 0.119162 0.011916 8391 5.0 -5.50 0.2318 396.72 395.21 0.186021 0.018602 5375 6.0 -8.90 0.1288 330.78 328.97 0.267570 0.026757 3737 7.0 -13.90 0.0407 283.71 281.60 0.326372 0.032637 3063 8.0 -25.00 0.0032 248.44 246.02 0.335378 0.033538 2981 9.0 -27.00 0.0020 221.03 218.30 0.299217 0.029922 3342 10.0 -18.40 0.0145 199.12 196.09 0.223996 0.022400 4464 12.0 -16.60 0.0219 166.30 162.67 0.051959 0.005196 19246 14.0 -22.70 0.0054 142.92 138.68 0.040814 0.004081 24501 16.0 -30.40 0.0009 125.44 120.58 0.053107 0.005311 18829 18.0 -21.00 0.0079 111.89 106.41 0.041321 0.004132 24200 20.0 -22.00 0.0063 101.09 95.00 0.032019 0.003202 31231 22.0 -30.90 0.0008 92.30 85.58 0.038201 0.003820 26177 24.0 -30.70 0.0009 85.01 77.66 0.045016 0.004502 22214 26.0 -26.80 0.0021 78.87 70.89 0.020085 0.002009 49788 28.0 -34.90 0.0003 73.65 65.03 0.080756 0.008076 12382 30.0 -27.30 0.0019 69.15 59.89 0.174578 0.017458 5728 32.0 -19.30 0.0117 65.25 55.33 0.213235 0.021323 4689 34.0 -16.30 0.0234 61.83 51.26 0.236441 0.023644 4229 36.0 -15.90 0.0257 58.82 47.59 0.260462 0.026046 3839 38.0 -17.60 0.0174 56.16 44.26 0.284539 0.028454 3514 40.0 -21.50 0.0071 53.79 41.21 0.308451 0.030845 3242 42.0 -28.50 0.0014 51.67 38.40 0.292568 0.029257 3418 44.0 -40.00 0.0001 49.77 35.80 0.174077 0.017408 5744 46.0 -36.50 0.0002 48.07 33.39 0.061357 0.006136 16298 48.0 -35.50 0.0003 46.53 31.13 0.007268 0.000727 137584 50.0 -40.00 0.0001 45.14 29.01 0.007676 0.000768 130272 52.0 -40.00 0.0001 43.88 27.01 0.013337 0.001334 74978 54.0 -34.40 0.0004 42.74 25.12 0.014857 0.001486 67306 56.0 -32.10 0.0006 41.71 23.32 0.015549 0.001555 64314 58.0 -32.10 0.0006 40.77 21.61 0.016153 0.001615 61908 60.0 -33.80 0.0004 39.93 19.96 0.016681 0.001668 59946 62.0 -36.60 0.0002 39.16 18.38 0.017282 0.001728 57864 64.0 -39.90 0.0001 38.47 16.86 0.014308 0.001431 69892 66.0 -39.60 0.0001 37.85 15.39 0.017419 0.001742 57409 68.0 -35.20 0.0003 37.29 13.97 0.025290 0.002529 39541 70.0 -32.00 0.0006 36.80 12.58 0.027499 0.002750 36364 72.0 -30.40 0.0009 36.36 11.23 0.027903 0.002790 35838 74.0 -30.10 0.0010 35.97 9.91 0.028381 0.002838 35234 76.0 -31.10 0.0008 35.63 8.62 0.028611 0.002861 34951 78.0 -33.20 0.0005 35.35 7.35 0.028953 0.002895 34538 80.0 -36.40 0.0002 35.11 6.10 0.027172 0.002717 36802 82.0 -40.00 0.0001 34.92 4.86 0.019671 0.001967 50837 84.0 -40.00 0.0001 34.77 3.63 0.010707 0.001071 93394 86.0 -40.00 0.0001 34.66 2.42 0.004678 0.000468 213775 88.0 -40.00 0.0001 34.60 1.21 0.004381 0.000438 228259 90.0 -39.20 0.0001 34.58 0.00 0.004353 0.000435 229749 9 of 13 Si �, -- tes r. ceeiipli.�i�c�e ��srp er ?s T- Mobile CH33 -259H - Buffalo Grove Golf Course Andrew:TMBX- 6516 -R2M Antenna Worksheet (110 Sector) Maximum Permissible Exposure (MPE): 1000 Height Frequency Downtilt ERP (Watts): 878 (feet): 120 (MHz): 1975 (Degrees): 0.0 Depression Slant Dist From Angle Relative Distance Structure Power Density Percent of Times (degrees) Relative dB Gain (meters) (meters) (uW /cm ^2) MPE Below MPE 0.1 0.00 1.0000 19810.64 19810.61 0.000075 0.000007 13405306 1.0 0.00 1.0000 1981.16 1980.86 0.007459 0.000746 134066 2.0 -0.50 0.8913 990.73 990.13 0.029827 0.002983 33526 3.0 -1.60 0.6918 660.66 659.75 0.067076 0.006708 14908 4.0 -3.20 0.4786 495.67 494.46 0.119162 0.011916 8391 5.0 -5.50 0.2818 396.72 395.21 0.186021 0.018602 5375 6.0 -8.90 0.1288 330.78 328.97 0.267570 0.026757 3737 7.0 -13.90 0.0407 283.71 281.60 0.326372 0.032637 3063 8.0 -25.00 0.0032 248.44 246.02 0.335378 0.033538 2981 9.0 -27.00 0.0020 221.03 218.30 0.299217 0.029922 3342 10.0 -18.40 0.0145 199.12 196.09 0.223996 0.022400 4464 12.0 -16.60 0.0219 166.30 162.67 0.051959 0.005196 19246 14.0 -22.70 0.0054 142.92 138.68 0.040814 0.004081 24501 16.0 -30.40 0.0009 125.44 120.58 0.053107- 0.005311 18829 18.0 -21.00 0.0079 111.89 106.41 0.041321 0.004132 24200 20.0 -22.00 0.0063 101.09 95.00 0.032019 0.003202 31231 22.0 -30.90 0.0008 92.30 85.58 0.038201 0.003820 26177 24.0 -30.70 0.0009 85.01 77.66 0.045016 0.004502 22214 26.0 -26.80 0.0021 78.87 70.89 0.020085 0.002009 49788 28.0 -34.90 0.0003 73.65 65.03 0.080756 0.008076 12382 30.0 -27.30 0.0019 69.15 59.89 0.174578 0.017458 5728 32.0 -19.30 0.0117 65.25 55.33 0.213235 0.021323 4689 34.0 -16.30 0.0234 61.83 51.26 0.236441 0.023644 4229 36.0 -15.90 0.0257 58.82 47.59 0.260462 0.026046 3839 38.0 -17.60 0.0174 56.16 44.26 0.284539 0.028454 3514 40.0 -21.50 0.0071 53.79 41.21 0.308451 0.030845 3242 42.0 -28.50 0.0014 51.67 38.40 0.292568 0.029257 3418 44.0 -40.00 0.0001 49.77 35.80 0.174077 0.017408 5744 46.0 -36.50 0.0002 48.07 33.39 0.061357 0.006136 16298 48.0 -35.50 0.0003 46.53 31.13 0.007268 0.000727 137584 50.0 -40.00 0.0001 45.14 29.01 0.007676 0.000768 130272 52.0 -40.00 0.0001 43.88 27.01 0.013337 0.001334 74978 54.0 -34.40 0.0004 42.74 25.12 0.014857 0.001486 67306 56.0 -32.10 0.0006 41.71 23.32 0.015549 0.001555 64314 58.0 -32.10 0.0006 40.77 21.61 0.016153 0.001615 61908 60.0 -33.80 0.0004 39.93 19.96 0.016681 0.001668 59946 62.0 -36.60 0.0002 39.16 18.38 0.017282 0.001728 57864 64.0 -39.90 0.0001 38.47 16.86 0.014308 0.001431 69892 66.0 -39.60 0.0001 37.85 15.39 0.017419 0.001742 57409 68.0 -35.20 0.0003 37.29 13.97 0.025290 0.002529 39541 70.0 -32.00 0.0006 36.80 12.58 0.027499 0.002750 36364 72.0 -30.40 0.0009 36.36 11.23 0.027903 0.002790 35838 74.0 -30.10 0.0010 35.97 9.91„ 0.028381 0.002838 35234 76.0 -31.10 0.0008 35.63 8.62 0.028611 0.002861 34951 78.0 -33.20 0.0005 35.35 7.35 0.028953 0.002895 34538 80.0 -36.40 0.0002 35.11 6.10 0.027172 0.002717 36802 82.0 -40.00 0.0001 34.92 4.86 0.019671 0.001967 50837 84.0 -40.00 0.0001 34.77 3.63 0.010707 0.001071 93394 86.0 -40.00 0.0001 34.66 2.42 0.004678 0.000468 213775 88.0 -40.00 0.0001 34.60 1.21 0.004381 0.000438 228259 90.0 -39.20 0.0001 34.58 0.00 0.004353 0.000435 229749 10 of 13 a T- Mobile CH33 -259H - Buffalo Grove Golf Course 11 of 13 S i te i fe i...z:'e nip3 vii ce�'e Ype r ?s Andrew:TMBX- 6516 -R2M Antenna Worksheet (240 Sector) Maximum Permissible Exposure (MPE): 1000 Height Frequency Downtilt ERP (Watts): 879 (feet): 120 (MHz): 1975 (Degrees): 0.0 Depression Slant Dist From Angle Relative Distance Structure Power Density Percent of Times (degrees) Relative dB Gain (meters) (meters) (pW /cm ^2) MPE Below MPE 0.1 0.00 1.0000 19810.64 19810.61 0.000075 0.000007 13390054 1.0 0.00 1.0000 1981.16 1980.86 0.007467 0.000747 133914 2.0 -0.50 0.8913 990.73 990.13 0.029861 0.002986 33488 3.0 -1.60 0.6918 660.66 659.75 0.067153 0.006715 14891 4.0 -3.20 0.4786 495.67 494.46 0.119298 0.011930 8382 5.0 -5.50 0.2818 396.72 395.21 0.186232 0.018623 5369 6.0 -8.90 0.1288 330.78 328.97 0.267875 0.026788 3733 7.0 -13.90 0.0407 283.71 281.60 0.326744 0.032674 3060 8.0 -25.00 0.0032 248.44 246.02 0.335760 0.033576 2978 9.0 -27.00 0.0020 221.03 218.30 0.299558 0.029956 3338 10.0 -18.40 0.0145 199.12 196.09 0.224251 0.022425 4459 12.0 -16.60 0.0219 166.30 162.67 0.052150 0.005215 19175 14.0 -22.70 0.0054 142.92 138.68 0.040861 0.004086 24473 16.0 -30.40 0.0009 125.44 120.58 0.052964 0.005296 18880 18.0 -21.00 0.0079 111.89 106.41 0.041210 0.004121 24265 20.0 -22.00 0.0063 101.09 95.00 0.031974 0.003197 31275 22.0 -30.90 0.0008 92.30 85.58 0.038391 0.003839 26047 24.0 -30.70 0.0009 85.01 77.66 0.044953 0.004495 22245 26.0 -26.80 0.0021 78.87 70.89 0.020057 0.002006 49858 28.0 -34.90 0.0003 73.65 65.03 0.080848 0.008085 12368 30.0 -27.30 0.0019 69.15 59.89 0.175000 0.017500 5714 32.0 -19.30 0.0117 65.25 55.33 0.213477 0.021348 4684 34.0 -16.30 0.0234 61.83 51.26 0.236710 0.023671 4224 36.0 -15.90 0.0257 58.82 47.59 0.260427 0.026043 3839 38.0 -17.60 0.0174 56.16 44.26 0.284863 0.028486 3510 40.0 -21.50 0.0071 53.79 41.21 0.309196 0.030920 3234 42.0 -28.50 0.0014 51.67 38.40 0.292901 0.029290 3414 44.0 -40.00 0.0001 49.77 35.80 0.174275 0.017428 5738 46.0 -36.50 0.0002 48.07 33.39 0.061427 0.006143 16279 48.0 -35.50 0.0003 46.53 31.13 0.007277 0.000728 137428 50.0 -40.00 0.0001 45.14 29.01 0.007685 0.000768 130124 52.0 -40.00 0.0001 43.88 27.01 0.013318 0.001332 75083 54.0 -34.40 0.0004 42.74 25.12 0.014931 0.001493 66973 56.0 -32.10 0.0006 41.71 23.32 0.015527 0.001553 64405 58.0 -32.10 0.0006 40.77 21.61 0.016130, 0.001613 615'46 60.0 -33.80 0.0004 39.93 19.96 0.016700 0.001670 59878 62.0 -36.60 0.0002 39.16 18.38 0.017235 0.001724 58019 64.0 -39.90 0.0001 38.47 16.86 0.014288 0.001429 69991 66.0 -39.60 0.0001 37.85 15.39 0.017438 0.001744 57344 68.0 -35.20 0.0003 37.29 13.97 0.025254 0.002525 39597 70.0 -32.00 0.0006 36.80 12.58 0.027531 0.002753 36323 72.0 -30.40 0.0009 36.36 11.23 0.027934 0.002793 35798 74.0 -30.10 0.0010 35.97 9.91 0.028414 0.002841 35194 76.0 -31.10 0.0008 35.63 8.62 0.028716 0.002872 34823 78.0 -33.20 0.0005 35.35 7.35 0.028875 0.002888 34631 80.0 -36.40 0.0002 35.11 6.10 0.027307 0.002731 36620 82.0 -40.00 0.0001 34.92 4.86 0.019693 0.001969 50779 84.0 -40.00 0.0001 34.77 3.63 0.010719 0.001072 93287 86.0 -40.00 0.0001 34.66 2.42 0.004683 0.000468 213532 88.0 -40.00 0.0001 34.60 1.21 0.004369 0.000437 228873 90.0 739.20 0.0001 34.58 0.00 0.004341 0.000434 230366 11 of 13 S i te i fe i...z:'e nip3 vii ce�'e Ype r ?s T- Mobile CH33 -259H - Buffalo Grove Golf Course Andrew:TMBX- 6516 -R2M Antenna Worksheet (240 Sector) Maximum Permissible Exposure (MPE): 1000 ERP (Watts): 878 Height (feet): 120 Frequency (MHz): 1975 Downtilt (Degrees): 0.0 Depression Slant Dist From Angle (degrees) Relative dB Relative Gain Distance Structure Power Density Percent of Times (meters) (meters) (NW /cm ^2) MPE Below MPE 0.1 0.00 1.0000 19810.64 19810.61 0.000075 0.000007 13405306 1.0 0.00 1.0000 1981.16 1980.86 0.007459 0.000746 134066 2.0 -0.50 0.8913 990.73 990.13 0.029827 0.002983 33526 3.0 -1.60 0.6918 660.66 659.75 0.067076 0.006708 14908 4.0 -3.20 0.4786 495.67 494.46 0.119162 0.011916 8391 5.0 -5.50 0.2818 396.72 395.21 0.186021 0.018602 5375 6.0 -8.90 0.1288 330.78 328.97 0.267570 0.026757 3737 7.0 -13.90 0.0407 283.71 281.60 0.326372 0.032637 3063 8.0 -25.00 0.0032 248.44 246.02 0.335378 0.033538 2981 9.0 -27.00 0.0020 221.03 218.30 0.299217 0.029922 3342 10.0 -18.40 0.0145 199.12 196.09 0.223996 0.022400 4464 12.0 -16.60 0.0219 166.30 162.67 0.052091 0.005209 19197 14.0 -22.70 0.0054 142.92 138.68 0.040814 0.004081 24501 16.0 -30.40 0.0009 125.44 120.58 0.052904 0.005290 18902 18.0 -21.00 0.0079 111.89 106.41 0.041163 0.004116 24293 20.0 -22.00 0.0063 101.09 95.00 0.031937 0.003194 31311 22.0 -30.90 0.0008 92.30 85.58 0.038347 0.003835 26077 24.0 -30.70 0.0009 85.01 77.66 0.044902 0.004490 22270 26.0 -26.80 0.0021 78.87 70.89 0.020034 0.002003 49915 28.0 -34.90 0.0003 73.65 65.03 0.080756 0.008076 12382 30.0 -27.30 0.0019 69.15 59.89 0.174801 0.017480 5720 32.0 -19.30 0.0117 65.25 55.33 0.213235 0.021323 4689 34.0 -16.30 0.0234 61.83 51.26 0.236441 0.023644 4229 36.0 -15.90 0.0257 58.82 47.59 0.260131 0.026013 3844 38.0 -17.60 0.0174 56.16 44.26 0.284539 0.028454 3514 40.0 -21.50 0.0071 53.79 41.21 0.308844 0.030884 3237 42.0 -28.50 0.0014 51.67 38.40 0.292568 0.029257 3418 44.0 -40.00 0.0001 49.77 35.80 0.174077 0.017408 5744 46.0 -36.50 0.0002 48.07 33.39 0.061357 0.006136 16298 48.0 -35.50 0.0003 46.53 31.13 0.007268 0.000727 137584 50.0 -40.00 0.0001 45.14 29.01 0.007676 0.000768 130272 52.0 -40.00 0.0001 43.88 27.01 0.013303 0.001330 75169 54.0 -34.40 0.0004 42.74 25.12 0.014914 0.001491 67049 56.0 -32.10 0.0006 41.71 23.32 0.015509 0.001551 64478 58.0 -32.10 0.0006 40.77 21.61 0.016112 0.001611 62066 60.0 -33.80 0.0004 39.93 19.96 0.016681 0.001668 59946 62.0 -36.60 0.0002 39.16 18.38 0.017216 0.001722 58086 64.0 -39.90 0.0001 38.47 16.86 0.014271 0.001427 70070 66.0 -39.60 0.0001 37.85 15.39 0.017419 0.001742 57409 68.0 -35.20 0.0003 37.29 13.97 0.025226 0.002523 39642 70.0 -32.00 0.0006 36.80 12.58 0.027499 0.002750 36364 72.0 -30.40 0.0009 36.36 11.23 0.027903 0.002790 35838 74.0 -30.10 0.0010 35.97 9.91 0.028381 0.002838 35234 76.0 -31.10 0.0008 35.63 8.62 0.028684 0.002868 34862 78.0 -33.20 0.0005 35.35 7.35 0.028842 0.002884 34671 80.0 -36.40 0.0002 35.11 6.10 0.027276 0.002728 36662 82.0 -40.00 0.0001 34.92 4.86 0.019671 0.001967 50837 84.0 -40.00 0.0001 34.77 3.63 0.010707 0.001071 93394 86.0 -40.00 0.0001 34.66 2.42 0.004678 0.000468 213775 88.0 -40.00 0.0001 34.60 1.21 0.004364 0.000436. 229133 90.0 -39.20 0.0001 34.58 0.00 0.004336 0.000434 230629 12 of 13 sites f.i.,.t..d I]> (� 3 t U f:.� Q.•..d Y b ? r �i �5 T- Mobile CH33 -259H - Buffalo Grove Golf Course Andrew:TMBX- 6516 -R2M Antenna Worksheet (240 Sector) Maximum Permissible Exposure (MPE): 1000 Height Frequency Downtilt ERP (Watts): 878 (feet): 120 (MHz): 1975 (Degrees): 0.0 Depression Relative Slant Distance Dist From Structure Power Density Percent of Times Angle (degrees) Relative dB Gain (meters) (meters) (NW /cm ^2) MPE Below MPE 0.1 0.00 1.0000 19810.64 19810.61 0.000075 0.000007 13405306 1.0 0.00 1.0000 1981.16 1980.86 0.007459 0.000746 134066 2.0 -0.50 0.8913 990.73 990.13 0.029827 0.002983 33526 3.0 -1.60 0.6918 660.66 659.75 0.067076 0.006708 14908 4.0 -3.20 0.4786 _ 495.67 494.46 0.119162 0.011916 8391 5.0 -5.50 0.2818 396.72 395.21 0.186021 0.018602 5375 6.0 -8.90 0.1288 330.78 328.97 0.267570 0.026757 3737 7.0 -13.90 0.0407 283.71 281.60 0.326372 0.032637 3063 8.0 -25.00 0.0032 248.44 246.02 0.335378 0.033538 2981 9.0 -27.00 0.0020 221.03 218.30 0.299217 0.029922 3342 10.0 -18.40 0.0145 199.12 196.09 0.223996 0.022400 4464 12.0 -16.60 0.0219 166.30 162.67 0.052091 0.005209 19197 14.0 -22.70 0.0054 142.92 138.68 0.040814 0.004081 24501 16.0 -30.40 0.0009 125.44 120.58 0.052904 0.005290 18902 18.0 -21.00 0.0079 111.89 106.41 0.041163 0.004116 24293 20.0 -22.00 0.0063 101.09 95.00 0.031937 0.003194 31311 22.0 -30.90 0.0008 92.30 85.58 0.038347 0.003835 26077 24.0 -30.70 0.0009 85.01 77.66 0.044902 0.004490 22270 26.0 -26.80 0.0021 78.87 70.89 0.020034 0.002003 49915 28.0 -34.90 0.0003 73.65 65.03 0.080756 0.008076 12382 30.0 -27.30 0.0019 69.15 59.89 0.174801 0.017480 5720 32.0 -19.30 0.0117 65.25 55.33 0.213235 0.021323 4689 34.0 -16.30 0.0234 61.83 51.26 0.236441 0.023644 4229 36.0 -15.90 0.0257 58.82 47.59 0.260131 0.026013 3844 38.0 -17.60 0.0174 56.16 44.26 0.284539 0.028454 3514 40.0 -21.50 0.0071 53.79 41.21 0.308844 0.030884 3237 42.0 -28.50 0.0014 51.67 38.40 0.292568 0.029257 3418 44.0 -40.00 0.0001 49.77 35.80 0.174077 0.017408 5744 46.0 -36.50 0.0002 48.07 33.39 0.061357 0.006136 16298 48.0 -35.50 0.0003 46.53 31.13 0.007268 0.000727 137584 50.0 -40.00 0.0001 45.14 29.01 0.007676 0.000768 130272 52.0 -40.00 0.0001 43.88 27.01 0.013303 0.001330 75169 54.0 -34.40 0.0004 42.74 25.12 0.014914 0.001491 67049 56.0 -32.10 0.0006 41.71 23.32 0.015509 0.001551 64478 58.0 -32.10 0.0006 40.77 21.61 0.016112 0.001611 62066 60.0 -33.80 0.0004 39.93 19.96 0.016681 0.001668 59946 62.0 -36.60 0.0002 39.16 18.38 0.017216 0.001722 58086 64.0 -39.90 0.0001 38.47 16.86 0.014271 0.001427 70070 66.0 -39.60 0.0001 37.85 15.39 0.017419 0.001742 57409 68.0 -35.20 0.0003 37.29 13.97 0.025226 0.002523 39642 70.0 -32.00 0.0006 36.80 12.58 0.027499 0.002750 36364 72.0 -30.40 0.0009 36.36 11.23 0.027903 0.002790 35838 74.0 -30.10 0.0010 35.97 9.91 0.028381 0.002838 35234 76.0 -31.10 0.0008 35.63 8.62 0.028684 0.002868 34862 78.0 -33.20 0.0005 35.35 7.35 0.028842 0.002884 34671 80.0 -36.40 0.0002 35.11 6.10 0.027276 0.002728 36662 82.0 -40.00 0.0001 34.92 4.86 0.019671 0.001967 50837 84.0 -40.00 0.0001 34.77 3.63 0.010707 0.001071 93394 86.0 -40.00 0.0001 34.66 2.42 0.004678 0.000468 213775 88.0 -40.00 0.0001 34.60 1.21 0.004364 0.000436 229133 90.0 -39.20 0.0001 34.58 0.00 0.004336 0.000434 230629 13 of 13 Sites3 fe Existing Coverage ExIstina UNITS Coverage Without Site CH33259H Best Server Legeml E a takisic Hd 33R ht Bnllding Coverage L +:H131 7 In Vehicle Coverage v. , On Sneer Coverage Hr ?J Busch P,d CH53034A . -.. Chrckar Ffd ed Towe r� CH3325 cc i un tice Rd State Hw 1N i. C IC 1322-96 c - Coverage Area: 100' Tower UNITS overac a With Pro osed I ite CH33259 00' Best Seivoi Leaeud \ I.H33195A Coverage Area: 75' Tower umizis,overagemi4t,ro osea s to azoa tutu - Best Seivei Legend Eatakisic Hd += H530336 „� III Balldluy Coverage CH.13700B lu Vehicle Coverage It)S""ttieetCovelage Srt Busch Rd vU �H53034A Checker Rd PIP e d QCH732I1A �Ow�Y` �}D�CH23053 Ctwn1 ne r+d VCH3325 • V" / E Lake C-K Rd -- - rV�f� =7 S' (f Sna HW yi 4 - o ,..��132 _ = CHe3028C undee Rd State Hxy 45 ;YT L4I 530180 H13225C -, t CH3319 is in QCH13229B 9 Coverage Area: 120' Tower UMTS Co era a With Prwe d S to 3 59 0' FRPMRP Best Server Legend Kd CH530336 .IIF III Building Coverage 44437006 in Vehicle Covelage PtE�Aptakisic pn Street (:Duet age - ?&rsch Rd H5303JA Checker Rd Z Pr e d 2' CH73217A _ oa�re r� �r;H23053 r, 1"TV Ca,n;y .-,nc• d _ '�7CH3325.�•. / E Lake Cook Rd -.ice I tV�E•�7 `4 132266 - o z _. un UCC Rcl t "f.i ti H.:;V lac • I �U t!i: i• F'. I ._ 30'180 H'13 ?250. \/CH3319) 5A VV —CH13221% 1 J I 3� ! { it �• "� J � v t 1 1 06- r\ ONE&M f 64, 03 ,R o CA) G) .7 A, 0 Z CO 0 0 . 1-14 W Lake Cook RO z Cr D X V 0 Cf E Maple ON 'n Hlr: W-T OTU • s Mobile e Oca COkUAOOUWW_ AT*C ng G LN 0 mulation isanartists depiction of a future installation. The actual construction may vary slightly in size, layout, color and texture from this simulation. y \ � � Q ! m� s� ELM R Eg n. Yttd �5 �. q. M f o r: 9 n. A «S �. r. _. _. _.. �:: 5F: ;aka .............. ... .................... ..... ........ .......... ........ _ .............. -£ xXXXX t z : ,T ... ; a . ; : x ;aka .............. ... .................... ..... ........ T 11 1,Mob*1em@- s-ticktogether SITE NUMBER: CH33 -259H JURISDICTION: VILLAGE OF SITE NAME: BUFFALO GROVE BUFFALO GROVE GOLF COURSE CiTY: BUFFALO GROVE SITE TYPE: RAWLAND COUNTY: LAKE _ VICINITY MAP z1 iz 53 - _ -- 45 _ \ N 14 _` 12 CONt i 53 b 2i „ PROJECT DESCRIPTION: NSTA31 T-YORIU M.MT CA901Ei3 ON A —'In PAD AT M.A ..w $ -R FACIUtt IS UNWNNtD. INITIAL BUIU) OUT: 9,ANTDUUS, ]}Z COAX RUNS. ],G91 CARNET ],1%AE CONTACTS APPUCANT i NDWtE USA M W. I YA0 AVENUE SUITE 100 LwcAGO. It 60631 h IiACT: J]FL MAW$ PROPERTY OIVNER CONTACT RURALO CRAVE w COURbE a ko 9ROVt &6WR9 0L1 BV }Ra F, 1FL (647) 459- - WNTA.: B PHR pRDpFRTY MAUpGEUENT GOIAPANY CONTACT-, N/A iEl: CIXliA.Cl: . UTILITIES• »nun UMLln: � (°ERDD� Tio, (wo) 2a] -D9D2 COIRACI: N A COMACL: N A U>U WMPPNY 1tLtt OLNPNry CONTACt -- OATAtt: -_ PROJECT TEA* dHGiiIIF.CI ZONING 4: PERMITTING W-T CDNYUIDCAINAV D61GN N A , . 1616 PRANY AVENUE H...TAIFS, R 6.92 PROlff (216)19 }5333 FAL (]24)193 -644f ACOUI51110N xT wm SueYEY9J6. Ma N/A 16]5 PPANY AYIDIUE XOffl1AN ESTAM IL 6.91 lEl: (114) 29J -63)3 FA% (124)19}6414 CdFTA.: RRAAMf YAROC FLCCTRICAL ENGINEER STRUCTURAI ENGINEER DROOP, Ate'— 2613 PRA.MAI AYT9R)E HO . ESTATES IL 60192 PHONE: (11Q2 o= FA%: (124) 29}6H6 Dotes Jo n SHEET INDEX: SEA DESCRIPTION: 2QNNC ORAWNCS REL: A SY:� IOD 511E PUN gA-urf EIMAl10N PROJECT LOCATION COORDINATES (NAD93) SITE ADDRESS IT, ­.N (MAD 8.3) BUR L ROVE 4 6 LONG 8]59'06AYw MAD 85) LAKE COUM 0D49 Aus� 5el.ar (xcw> DATA O9TAWED RtOH 2C LEt1ER I T' EscmPnD _ LOCATION MAP. _,,A� 6 SiIE LACAION �y. Q A o TAKE COOK ROAD �� 9T. YARYS PKWY p 8 m � E NCKOItY Qp A{E. 3 l �� 34 BUILDING SUMMARY OCfUPANCY CLASgFHpRON:_ WNAYNED lD£COYNUNMAlI0N6 FAPUtt, SI sDLA$$fFl�Gll� H I CTI RAN,MO SITE INFORMATION: CH33 -259H BUFFALO GROVE GOLF COURSE 48 RAUPP BLVD. BUFFALO GROVE, IL 60089 LAKE COUNTY W- T - NUMBER: MCC SHEET TREE TITLE SHEET [SHEET NUMBER T -1 %DT SfALk: 1:1 O 11'riJ' PROPERTY SUMMARY: PROPERtt ADDRESS: ZONING: r uPP RLw. Ra RU6FIA0 CRWE IL fi00R9 ASSESSOR'S PARCEL NUMBER lAPNI: 15- 32- WS-D31 APPROVALS: PDONC APPROVAL CP ME JJFISD1C11oN, ME iOLLOMNG PAR11E6 HAYS RENENID TJE DESAN 1xDR NNCOONAL R6PON 7". AND RA APPROATD TITS PAOJFM FRi CON6RNC110N, T0.YITRACTCRS WY NDT 9MT COA.'SIfNCiIWI —T A IIHM TD m0oETD (NR) TROA u &EE P�L.NAME 22LAWBE PBIi uNq.ORD PREOLN, NCR DE\4W. uCR C*Rv.. MSP, � Y� WFRA11WI5 _ SAC/10NNG pay URU1&5 APPLICABLE CODES RuWleg/DreilNg Cade 19C 20D6 m ammdM 6JrvcWml Lack JCL 2006 os omxd[d Plumbm9 CPtic 6linolr 51ak RumE'vig Cede 1w{ a mnmd<tl N«r W d Latic ba -6 m emended Dxlhd Cede NEC 2005 m amended ­/u. WAY Ce'.: NFPA moo 101 Ile S wy Cede DRIVING DIRECTIONS DOIECiNXES fR0i1 d11CA00 01NRE DI—A.- AWIM.. IRP LNDACO "ARE WHINATIM& AMPWR. TAM RAW (MWI) CATD 1-190. AT DOT 1D, TURN RNIT ONTO RAW. eMU. ROM- MM DNTD — (TRI -STATE MWAY). RRtR R T ORTD RAW AID KEEP RDNT TO STAY ON RAW. TURN IEEE (FIST) ONTO SR-R3 (W. 12TH sT). ROAD NAL a -I- TO (1'1) 12` Si. NRN R T (SOUTH) ONTO (6) `DNC AVE TURN � (FAST) WO 14M a.. MEN O MIAMY MAR UFI (NORM -Ro') ONTO MW Al£ M. R,.1 (FASO CHID LOCAL RDAD(S) AAU AR M. AT Slit T R - Mobile d 49SD BRTN acn Nn AY 9 IOD a6a, R uxos �s em31 PIJINS PREPARED BY: W -T COMMUNICATION DESIGN GROUP. LLC. .,. PAS°i°"aomaw SEAL:oan uwtUo to oaA¢1 W. awarJJ_ GATE: 0{.13.10 DESCRIPTION: 2QNNC ORAWNCS REL: A SY:� IOD T' EscmPnD A SITE INFORMATION: CH33 -259H BUFFALO GROVE GOLF COURSE 48 RAUPP BLVD. BUFFALO GROVE, IL 60089 LAKE COUNTY W- T - NUMBER: MCC SHEET TREE TITLE SHEET [SHEET NUMBER T -1 %DT SfALk: 1:1 O 11'riJ' / / / .... COUNT Y COOK COUNTY / 2axrnM ASeHP1T Wax ro ` :::: ::: \ it \ \\ / rnsnxc uxoscAPNA ro / - —uuAw Imw / Rw51aWNO�; HW6E iO / \��' FYJSMNG ASPHALT WAD( j - 1:�:':::::: _PdPM (IYPJ / ��� , ' "� D9rnxc uvroscAPlxc To \ REUant (TrrJ \ TD.W PFDESTN. ro eE \ DiVl CONIRRCIOR TO cAL UMW LaAn9N a Fl¢D NM+ LOLL uTOn MNPANY. PRLPG9m 5 -V NICE T- Mu \ D7NTY EA9ExdT. SEE SORYCY FOR \ M6CPPTKXI. �— E%LAT6YG 1NAN9FO TO \ \ G . N �EAIFY 00NTRAm \ WM LOMN IN FIDD LOCAL UMN nM \ MPAMI. 'PROP09D) 20-0' RIDE \ T-NMSE A= EMBIMT. SEE SDRVEY FOR \ DLSLRPMIH. \ VSIWG DRD TO RDIAIN \ \ T o .Mobile stkxf 8590 M. NAM ADNL SINIE IW ONICAW. D S 60901 PLANS PREPARED BY: W -T COMYDNIC11T10N DE a GROW PLC. m en mRnn BEAU ancea�Y3B'1t NsvuaJJ- DATE: 0413.10 DESCRIPTION: ZCxING MAWNC9 REL: A BY: NLO R 0 DATE D PTION: 0 A 0 SITE INFDRMATION: CH33 -259H BUFFALO GROVE GOLF COURSE 08 RAUPP BLVD. BUFFALO GROVE, IL 80089 LAKE COUNTY W -T - WNISSN: TIW0 SNEEf TITLE SITE PLAN SHEET NUMBER: A -1 m AVNACFR OSNRACTpT DO ME PUBIC AULI D PPoWATE LOG,nNG 6ERVNE W ORDER TOU­YEAND PROTECT ALL SURFACE UNJDCx DO W BCAE OW FOR MY E— (BADE UBNIES y4w, - On— EUBBED AND .. TO __.. WN_- wm ALL — UDU1. . . — AND COORWAIE MY REPAIRS WV REVEDIVE UTNM ­1MY, —M.- ro YrALFY ALL IffidYY AND A2 ,M� 11 I Im TO B.BIBUOM. —, ­ WD T-.Ml — SIBRIMM M V MY ­B`M— BE— — M ­M — RPSTFdE M. WXR .1 OANAQT AREAS mm BY mm.. N PROPODE) UNDSO01B. .DO" m, mm AAEA /'21 PROPM mm W� ro �Rt —M . . . . . . . . . . . . . PROOOSED T- 'w-w TALL PROPOSED r -NOWIE ANTENNAS w ]PER =TM)- N PROPODE) UNDSO01B. .DO" m, mm AAEA /'21 PROPM mm W� �Rt —M . . . . . . . . . . . . . .............. ... ;,---7�� mg FROF m V D- 0' - NORTI ' ' ~� mum GAMMA BETA \ A�U. 1W .PB.Dm v M. v" �j A\ X11 I� Ai., EBY, D- =61 PROPOSED V-D• wE Imm. DO NG �Rm To BE V.W. OO=AO1DR To VWIFY TRIM FIELD mm UXk uwv __1 \------------------- - - - - -- — — — — — — — — — - ------------------------------------ Z T - -Mobile dick tow"m CNLACD, NUMBS 606]1 PLANS PREPARED BY: — v ff- W-T COMMUNICATION DES jGW �QROUP LLC. 'E: TDEWRIPTIONTREL.. ', ­ BBBOB A CH33-259H BUFFALO GROVE GOLF COURSE 40 R UPP BLVD. BUFFALO GROVE, ILSONS LAKE COUNTY — M "m Ai10O63] SITE PLAN A-2 T • •Mobile 5±50 6RM MANR AVENUE, SkIE TW dMACO, N1RifXR 60631 PLANS PREPARED BY: ■ W-T COMMUNICATION DESIGN GROUP. cNCx PN. AcpaV »twa mrx mF+�W4N11 t>naFAyf/DyAE xN1m1JJ- 'E: DESCRIPTION: REL; .NTkTNxCMAW. T A CH33 -259H BUFFALO GROVE GOLF COURSE "RAUPP BLVD. BUFFALO GROVE, IL 66064 LAKE COUNTY W -T = NJwm. ­w E ELEVATION, W ELEVATION A -3 ftOf SCNC u+ o tl'dY /�PPOPGSEp R'-0' HILN uONINWG BAW / IY NA YIN PROPOSm 6' -p' XIG4 IIdIiNING n.l l lOP OP M DO ANiFN I�M� t3 NA NR! A. PRS -0't \— // PROPO4D m> GF A D N i PROPDRED TCP DF NLNOPLiE AAU TYO ANIENNA RM C£NIDt MDR" 061115 PAN�1 ANF1lNAS ANORE]I A RRt6 -R1M PREP0.GD WP DF MCND:D.F AND 1110 PRDPpSED T-NDBCE PANEL AximNAS Y IPD' -D f m (TP. DY 3 PFR RAD cwpD �ANiFXxA RN CFIIiFA ftEM /IMB%- 651E -ELI 'YT2� =Ei1 (TYP. OP 3 Pm RAD CDRm) PROP03D ­F ANTENNA RAD C£HiW I PAOPOSm FlInWE CMPoFA pN10NA5 ROPCSPD 7 P NNRE CIRRIEA ANTENNAS PRN+OFED NNRE .N m RID CENTER PHOP06m i -MORN£ 130' -D' NCNCP0IE PPOPpSfA T- N0611E Ito' -M Ng10P6.E ro eE DxDR uwr x0115 LOWER m BE COLOR GRAY NOTE TO GENERAL GDNTRAC TOR NOTE TO GENERAL CONTRACTOR NO WORK IS TO BE PERFORMED ON THIS TOWER WITHOUT RENEW OF THE APPROVED NO WORK IS TO BE PERFORMED ON THIS STRUCTURAL ANALYSIS, IF ANY TOWER WITHOUT REVIEW OF THE APPROVED DISCREPANCIES ARE FOUND THE GENERAL STRUCTURAL ANALYSIS, IF ANY CONTRACTOR SHALL NOTIFY ENGINEER IN DISCREPANCIES ARE FOUND THE GENERAL WRITING. AT NO TIME WILL ANY ADDITIONAL CONTRACTOR SHALL NOTIFY ENGINEER IN ANTENNAS ANTE INSTALLED WITHOUT WRITTEN WRITING. AT NO TIME WILL ANY ADDITIONAL CONSENT FROM TOWER ENGINEER. ANTENNAS BE INSTALLED WITHOUT WRITTEN CONSENT FROM TOWER ENGINEER, AtY! R' AZ 2Y µ,DE MEDIANICAL m1c GATE .' DFWRAR c' fAEO: S n m. z " X PF®o;m a w P_ W! PVNN m RDDF II � DECIXfAIIVE MOOD 3D-V3 �� I'I1 i1 ll'III III IG VIII IL III IiIIll'� 'IF II 1 III j pI Ij I�11.i Ili PmPpSFp T -MOBLLE II PROPOSm T -MD&I£ _DSCAPDN. I1l54px I' .YII N1y�APM4 (NiSAWi III - III I I'Ir. T m - Is -D•t ARBORVRN I ro ff SPACm R'41 D.C. SPACm s -) D D.c PROP0.5FD roxtR Fouxoanox aRCxm BY OMERS RFFTR PROPOSED iDR EWIXDATION ro SIINCNRAL AND NOiG OE44Nm BY iNERZ REFFA o 51RUCNRN RMNIOAIWN pRAVANCS CONIRACiCR m uEE PRDPER mRWE ro AHD A91E FWNDAnON DRAVINCS. NMmCN g1Fx NRIAWNG ANp nGHTDRNG CWNECICRS ro INSURE PROPFA FlT. CDViRACroR ro UY PPOPER 1giWF R� LOC nT. NDIE CDNIRaCiIXt SHALL Bf F5PON19JE FM ' VFII ND T RNN 156 CDNFlGURAMN ANp iiiY - YC61LE AND mDNEERING FWM WNiRACroR SNALL BE RESPONS101E Fpt VERGING RVAI PF CONFlpIRAl10N Mq M'Ii X NN DIGCRFPANDES. NDTE CON1RACroR ro VERUY ALL X6tl116 ANO NDiF: .9­ N REm PRDR ro CCN6IRUCTON. CWliRa. SNAL VFAIFY ALL mIAL Alp CdREClIOx LOCAIIEW$ WIiN i- Ai■IIE CON1RACroP SMALL NOANY NOtUY i -NOmE AM ENCNDALVO PRN NI1X PNY DIYRIPANCES. ND1E CON1AACiDN m ATJUiY ALL Ipg11S AND ,pT, A3NU'MG N FEm PWCR TD COXSiRIICINIK CDIIRACNIR $HALL KAIFY ML FlNN MSOma FNRNEFFN6 nRN OF EPANFSS FNCVNEm. AF ENONEDf, AND MET -1W5 86'CRE PROC®IXG. PA0.2 TO NSfP1L1TON. NNIRACI� 91ALL xD11iT T- 110811E AND CgINFCAW! LaAIWMS 1NA1 i -YDNEE ENCNFFTIHu RRN OF PNY DI REPANCIES ENGNm4 R£ ETYNEVf. A19 NEf -OPS BFFgtF PROCEEDING. PAlgt 10 W5IAWRON. EAST ELEVATION 9 WEST ELEVATION T • •Mobile 5±50 6RM MANR AVENUE, SkIE TW dMACO, N1RifXR 60631 PLANS PREPARED BY: ■ W-T COMMUNICATION DESIGN GROUP. cNCx PN. AcpaV »twa mrx mF+�W4N11 t>naFAyf/DyAE xN1m1JJ- 'E: DESCRIPTION: REL; .NTkTNxCMAW. T A CH33 -259H BUFFALO GROVE GOLF COURSE "RAUPP BLVD. BUFFALO GROVE, IL 66064 LAKE COUNTY W -T = NJwm. ­w E ELEVATION, W ELEVATION A -3 ftOf SCNC u+ o tl'dY i� GRASS Y, cl Q x 1� >Q �,}�p4b °� GRASS e ,p 1 6 PO/ �OF BE0'/NN/ 66 � / PR VERSE EA / 272 5 �A685 � [JE e° °yam ti E GE U t4 5 ASPHALT V� �P A SQ WOOD RETAINING WALL fE7E, apilb'E'.! . 'A 1-01 LINE TABLE LINE I BEARING DISTANCE L1 _ N 5540'02" E 25.67' L2 _ S 3C19'58" E 13.00' L3 S 55'40'02" W 25.67' L4 N 3419'58" W 13.00' L5 N 55'40'02" E 6.25' L5 N 55002" E 5.00' L7 S 3419'58" E 40.38' L8 N 55'40'02" E 14.00' L9 S 34'19'58" E 8.00' L7O S 55'40'02" W 14,00' U i S 3419'58" E 7.20' ' L12 N 3419'58" W 58.24' PLAT OF SURVEY i A -mobil PROPOSED LEASE AREA DESCRIPTION THAT PART OF VILLAGE CAMPUS SUBDIVISION BEING A SUBDIVISION IN THE SOUTHEAST WARIER OF SECTION 32 8660 W. BryD MRwrAva TOWNSHIP 42 NORTH, RANGE 11 EAST OF THE THIRD PRINCIPAL MERIDIAN IN LAKE COUNTY AND IN THE Bud. 100 NORTHEAST QUARTER OF SECTION 5, TOWNSHIP 42 NORTH, RANGE 11 EAST OF THE THIRD PRINCIPAL MERIDIAN. Cwmp IIGDos60881 COMMENCING AT THE SOUTHWEST CORNER OF SAID VILLAGE CAMPUS SUBDIVISION; THENCE NORTH 34 DEGREES OFFICE: (78)4446100 20 MINUTES 09 SECONDS WEST ALONG THE WESTERLY LINE OF SAID SUBDIVISION, 26235 FEET; THENCE NORTH FAX; (M) 444-5500 55 DEGREES 40 MINUTES 02 SECONDS EAST, 246.85 FEET TO THE POINT BEGINNING; THENCE CON71NIANG NORTH N 55 DEGREES 40 MINUTES 02 SECONDS EAST, 25.67 FEET; THENCE SOUTH 34 DEGREES 19 MINUTES 58 SECONDS EAST, 13.00 FEET; THENCE SOUTH 55 DEGREES 40 MINUTES 02 SECONDS WEST. 25.67 FEET; THENCE NORTH 34 DEGREES 19 MINUTES 58 SECONDS WEST, 1100 FEET TO THE POINT OF BEGINNING, CONTAINING 334.00 SQUARE FEET, MORE OR LESS, ALL IN WOK COUNTY, IWNOIS. PAO.E07 NO. 808149 DMWN 8Y• DAM PROPOSED UXITY EASEMENT DESCRIPTION THAT PART OF VILLAGE CAMPUS SUBDIVISION BEING A SUBDIVISION IN THE SOUTHEAST QUARTER OF CIIEOKED 8Yiy0 SECTION 32, TOWNSHIP 42 NORTH, RANGE 11 EAST OF THE THIRD PRINCIPAL MERIDIAN IN LAKE COUNTY AND IN THE NORTHEAST QUARTER OF SECTION S. TOWNSHIP 42 NORTH RANGE 11 EAST OF THE THIRD PRINCIPAL MERIDIAN: COMMENCING AT THE SOUTHWEST CORNER OF SAIU VILLAGE CAMPUS SUBDIVISION; P00.o WOWC A/0M THENCE NORTH 34 DEGREES 20 MINUTES 09 SECONDS WEST ALONG THE WESTERLY UNE OF SAID SUBDIVISION, 262.35 FEET; 714ENCE NORTH 55 DEGREES 40 MINUTES 02 SECONDS EAST, 246.85 FEET; 00 10 20 40 THENCE SOUTH 34 DEGREES 19 MINUTES 58 SECONDS EAST, 1100 FEET; THENCE NORTH 55 DEGREES 40 MINUTES 02 SECONDS EAST, 6.25 FEET TO THE POINT OF BEGINNING; THENCE CON71NUING NORTH -- 55 DEGREES 40 MINUTES 02 SECONDS EAST, 5.00 FEET; THENCE SOUTH 34 DEGREES 19 MINUTES 58 MBAR SCALE SECONDS EAST, 40.38 FEET; THENCE NORTH 55 DEGREES 40 MINUTES 02 SECONDS EAST, 14.00 FEET; ° THENCE SOUTH 34 DEGREES 19 MINUTES 58 SECONDS EAST, 8.00 FEET; THENCE SOUTH 55 DEGREES 40 MINUTES 02 SECONDS WEST, 14.00 FEET; THENCE SOUTH 34 DEGREES 19 MINUTES 58 SECONDS EAST, 7.20 FEET; THENCE NORTH 89 DECREES 42 MINUTES 30 SECONDS EAST, 99.52 FEET; THENCE SOUTH 00 DEGREES 17 MINUTES 30 SECONDS EAST, 5,00 FEET; THENCE SOUTH 89 DEGREES 42 E�UI IN I I I I I' MINUTES 3D SECONDS WEST, 102.18 FEET; THENCE NORTH R DEGREES 19 MINUTES 58 SECONDS NEST, SCALE: 1" = 20' 58.24 FEET TO THE POINT OF BEGINNING, CONTAINING 900.79 SQUARE FEET, IN GOOK COUNTY, RLNOS. N 8M4 V' £ 9952' S 89V -PaO' W _�/ M..18' PROPOSED UTIL/TYEASSf, -- GRASS 0 Vt 50� �P P 9Q 5 007730' E _ m RIGHT OF WAY UNE OF LAKE -GOOK ROAD; THENCE SOUTHWESTERLY 2268 FEET ALONG A CURVE TO THE RIGHT HAVING A RADIUS OF 1859.86 FEET (CHORD BEARS SOUTH 83 DEGREES 29 MINUTES DO SECONDS WEST, 22.68 FEET , THENCE NORTH 34 DEGREES 40 MINUTES 14 SECONDS WEST, 415.07 FEET, THENCE SOUTH 55 DECREES 39 MINUTES 51 SECONDS WEST, 213.99 FEET; THENCE SOUTH 84 DECREES 08 MINUTES 41 SE0014DS WEST, 70.81 FEET; THENCE NORTH 34 DEGREES 47 MINUTES 06 SECONDS WEST, 98.12 FEEL THENCE NORTH 05 DEGREES 44 MINUTES 55 SECONDS EAST, 30.49 FEET; THENCE NORTH 55 DEGREES 40 MINUTES 02 SECONDS EAST, 55.81 FEET TO THE POINT OF BEGINNING, CONTAIN24G 17,519.36 SQUARE FEET, IN COOK COUNTY, WNOIS PARENT PARCEL DESCRIPTION VILLAGE CAMPUS SUBDIVISION BEING A SUBDIVISION IN THE SOUTHEAST QUARTER OF SECTION 32, TOWNSHIP 43 NORTH, RANGE 11 EAST OF THE THIRD PRINCIPAL MERIDIAN IN LAKE COUNTY AND IN THE NORTHEAST QUARTER OF SECTION 5, TOWNSHIP 42 NORTH, RANG It EAST OF THE THIRD PRINCIPAL MERIDIAN IN COOK COUNTY, ACCORDING TO THE PLAT THEREOF RECORDED DECEMBER 214 1988 AS DOCUMENT NUMBER 88556866 IN COOK COUNTY, IWNOIS. STATE OF ILLINOIS COUNTY OF COOK � ss CH33 -259H WE W -T LAND SURVEYING, WO DO HERESY OECI.ARE THAT WE HAVE SURVEYED THE ABOVE DESCRIBED PROPOSED LEASE AREA AND THAT THIS PLAT 19 CORRECT BUFFALO GROVE GOLF COURSE A REPRESENTATION OF SAID SURVEY. THIS PROFESSIONAL SERVICE CONFORMS TO THE CORRFJffkLQVDB MINIMUM STANDARDS FOR A BOUNDARY SURVEY. v \Ao 14iN GIVEN UNDER OUR HAND AND SEAL THIS 23rd p,4��IDFAT ROFFMAN ESTATES, ILLINOIS, e1kF 84 RAUPy5ROAD r W -T LAND SURVEYING, INC. _ 4 % `�gi9C9R P48 9 BIR:ET TIRg i ` « LANG BURVEV LS -1 8OF P. OF P. BiEEfB WANJO L MATCI PLS ®035- 003556 E RE i �L LYN \�\ ffir"LAT OF SURVEY NOTES: t. BENCHMARK - FINISHED FLOOR OF THE ONE STORY BRICK BUILDING (TAKED ON THE WEST SIDE). ELEVATION-682A3' 2 PERMANENT INDEX NUMBER: 03 -05 -200 -009 3. THE LOCATION OF UNDERGROUND UTILITIES WAS DETERMINED BY FIELD OBSERVATION AND VISBLE MARKINGS ONLY. 14. LATITUDE: N 42109'10.32' LONGITUDE: W 87'59'06.42' (NAD 83) S. FIELD WORK COMPLETED: 06 -13-09 6. SURVEY PREPARED WITHOUT THE AID OF A TITLE REPORT, REFER TO A CURRENT TITLE REPORT, DEED AND LOCAL CODES FOR ANT EASEMENT, BUILDING SETBACKS AND OTHER LOCAL RESTRICTIONS NOT SHOWN HERON. 7. ACCORDING TO OUR INTERPOLATION OF THE FLOOD INSURANCE RATE MAP THIS SITE IS LISTED AS BEING IN A ZONE 'X', DESCRIBED AS -AREAS DETERMINED TO BE OUTSIDE THE 0.22 ANNUAL CHANCE FLOODPLAIN' PER F.E.M.A, PANEL NO. 17031CWJ63J DATED AUGUST 19, 2009. & SURVEY PREPARED FOR: W-T COMMUNICATION DESIGN GROUP, LLC / 224- 293 -6333. `S C/NE CF NE SF T/4 OF SECAON ,i2 -4J-11 `N. LINE OF 791E NE 1/4 OF ZOA011 5 -42 -11 N F I I PROPOSED LEASE AREA �.c (.SEF,;7/EETLS -!J � F a I I o 00 � FOUND MONUML7✓T AT CORNER �oyL9 Y t p# rAu p�.pN19GB� _ OD MANJO 1. MA C - P -#035-O X IRES„ tl Ao f a 8 rN`OF4LL! °... lull +° L A K E C O U N T Y COOK couNrY - - VILLAGE CAMPUS SURD /V /S /ON RECORDED DECEMBER 2nd 1988 AS DOCUMENT #88556866 N xp-- 06' .19 99 t� 5oll5 CA PROPOSED ACCESS EASEMENT POINT OF L•OMMENGWR17 57Y CORNER OF I "6F CAMPUS SUBDIIOWON FOUND MONUMENT FOZIAO MONUMENT AT CORNER AT CORNER - 144,22 237.20' ° NOR7N R/ONT OF WV LINE OF LAKE Li X ROAD FOUND MONUMENT AT CORNER � '��[�1 .. J.9T1V ".11° bfie° . N 0 O- 8550 W. Bryn Mewl Ave. OQA Sub 100 Chl.9" INnoie80681 ' 9$• OFFICE: (173)444-6400 (773)444 -SND NFAX �. Irnweu° nu aunwr L 13'7 DRAWN BY, DAAt gECI® BX MWO ROD WORK, FOUND MONUMENT AT CORNER FhT°uBDU a�IN�c. SCALE: 1" 100' es= 00 50 100 200 BAR SCALE ~s_ RAG>= 1B59,B6' -off f X68' 00� � N CH33 -259H BUFFALO GROVE GOLF COURSE 484 RAIAP ROAD BURFALA aL som ORMT TITLE LAND SURVEY IPW STATE OF ILLINOIS) SS. COUNTY OF COOK ) CERTIFICATE I, Janet M. Sirabian, certify that I am the duly elected and acting Village Clerk of the Village of Buffalo Grove, Cook and Lake Counties, Illinois. I further certify that on, May 17, 2010 the Corporate Authorities of the Village passed and approved Ordinance No. 2010 -29, AN ORDINANCE APPROVING A SPECIAL USE IN THE 'R -4 DWELLING DISTRICT VILLAGE OF BUFFALO GROVE, COOKAND LAKE COOUNTIES, ILLINOIS Buffalo :Grove Golf Course 48.. Raupp Boulevare T- Mobile , Central, LLC provided by its terms that;itAould be, published in pamphlet form. The pamphlet form of Ordinance No, 2010 -29, including the Ordinance and a sheet thereof, was prepared, and a copy of such Ordinance was posted in and at the Village Hall, commencing on May 17, . 2010 and continuing for at least ten days thereafter. Copies of such Ordinance were also available for public inspection upon request in the Office of Village Clerk. Dated at Buffalo Grove, Illinois, this 18th day of May, 2010. V age Clerk V By L 5/17/2010 ORDINANCE NO. 2010-29 AN ORDINANCE APPROVING A SPECIAL USE IN THE R-4 DWELLING DISTRICT VILLAGE OF BUFFALO GROVE, COOK AND LAKE COUNTIES, ILLINOIS Buffalo Grove Golf Course 48 Raupp Boulevard T— Mobile Central LLC Proposed telecommunications facility — antenna and tower WHEREAS, the Village of Buffalo Grove is a Home Rule Unit by virtue of the Illinois Constitution of 1970; and, ' WHEREAS, the real property legally described in EXHIBIT A ( "Property") attached hereto'' is zoned in the R-4 One - Family Dwelling District with a special use for a public golf course and related facilities; and, WHEREAS, the Village of Buffalo Grove is the Owner of the Property; and, W "EREAS, the Owner proposes to enter into a lease with T- Mobile Central ?LC, a Delaware limited liability company to construct a communications antenna and tower (120 feet in height) and a ground -level equipment shelter for wireless communications pursuant to the following exhibits: EXHIBIT A Legal Description EXHIBIT B Narrative concerning compliance with special use criteria of Buffalo Grove Zoning Ordinance EXHIBIT C Letter dated May 5, 2010 by Sanjay Jaisingani, RF Engineer, concerning service coverage for area adjacent to proposed site EXHIBIT D Letter dated May 12, 2010 by Matthew J. Butcher, P.E., concerning interference with public safety communication systems 2 EXHIBIT E RF (radio frequency) Emissions Compliance Report dated May 10, 2010 by David Charles Cotton, Jr., Licensed Professional Engineer EXHIBIT F Maps of existing service coverage and coverage areas for proposed tower EXHIBIT G Photo simulations of proposed tower at view locations adjacent to site EXBHIT H Site plan, elevations and plat of survey (6 sheets, including LS -1 and LS -2 dated 9/24/2008;. and T -1, A -1, A -2 and A -3) dated 4/23/2010 by W Communication Design 'Group, LLC WHEREAS, Insite Real Estate Inc., as agent for T— Mobile Central LLC, a Delaware limited.` liability company, has submitted a petition requesting approval of a special use for a . telecommunications facility including a tower, antenna` and equipment shelter pursuant to the provisions and requirements of Chapter 17.34 of the Village Zoning Ordinance; and, ' -J WHEREAS, notice of the public hearing concerning the petition for the special use was'given' and the public hearing was held by the Buffalo Grove Plan Commission on April 7, 2010; - and; ~.,' WHEREAS, 'the Plan Commission determined, pursuant to findings based on the testimony, presented at the public hearing, that the criteria for a Special Use as set forth in Section 17.28.040 o - the Vill 'Z age's oning 'Ordinance have keen met and the special use is an appropriate use -of the Property and VMI not unduly affect adjacent properties; 'and, WHEREAS, the Corporate Authorities of the Village do hereby find that the proposed cellular communications antenna and tower meet the special use criteria as set forth in Section 17.28.040 of the Buffalo Grove Municipal Code and will comply with the provisions and requirements set forth in Chapter 17.34 of the Village Zoning Ordinance, and specifically make the following findings and conclusions regarding the proposed cellular communications antenna and tower ( "telecommunications facility "): 1. It has been demonstrated that coverage for T— Mobile's wireless service in the area of the proposed telecommunications facility would be improved by construction of the proposed tower and antenna thereby allowing greater cellular telephone use serving the public convenience not only at the location of the installation but throughout the projected coverage area, and the establishment, maintenance and operation of the telecommunications facility will not be detrimental to or endanger the public health, safety, morals, comfort, or general welfare. 2. The nature and intensity of the proposed facility will be in harmony with the appropriate and orderly development of the district in which it is located. 3 3. The distances to the nearest residences, the location of the site, and the open golf course area adjacent to the site indicate that there will not be detrimental effects or injury to the use and enjoyment of other property in the immediate vicinity of the subject property, nor will such use substantially diminish and impair other property valuations within the neighborhood. 4. The nature, location and size of the telecommunications facility will not impede, substantially hinder or discourage the development and use of adjacent land and buildings. 5. Utilities necessary to serve the telecommunications facility are adjacent to the site; there is adequate access to the site from the adjacent existing parking lot and street; the proposed improvements. will; not have any significant: impact upon drainage in the area; and any necessary, facilities for the special use have been or,Will be provided .' . 6. The telecommunications facility will require maigtenance visits only several times a year, and the facility, can. be served by existing parking,and paved acces$.. Said access is located so that there will not be traffic congestion or hazards adjacent to the site or in'the public streets. 7. The special use in all other respects conforms to the applicable regulations of the R-4 zoning district ? except as such regulations are varied in this, Ordinance NOVA, THEREFORE, BE IT ORDAINED` BY THE PRESIDENT AND BOARD OF ' TRUSTEES OF THE VILLAGE OF BUFFALO GROVE, COOK AND LAKE COUNTIES, r I LINOIS, Section 'l . _ This ordinance is made pursuant to and in accordance with the Village's Zoning Ordinance and the Village's Home Rule powers. The preceding whereas clauses are hereby made a part of this Ordinance. Section 2. The Corporate Authorities hereby approve an amendment to the Special Use for the Property legally described in EXHIBIT A attached hereto. Section 3. The special use is subject to the following: A. The following variation of the Village Zoning Ordinance is hereby granted: Section 17.40.020.B. — to allow a tower height of 120 feet instead of the standard building height of 35 feet in the R-4 District; B. The following variation of the Village Fence Code is hereby granted: Section 15.20.040 — to allow fencing 8 feet in height to screen the ground — level equipment shelter area, and the garbage dumpster area serving the restaurant and clubhouse building. 4 C. The appearance and materials for the fences and gates depicted on Exhibit H (site plan and elevations) hereto are subject to review and approval by the Village. D. A final landscaping plan shall be submitted to the Village Forester for review and approval prior to removal of trees, site preparation work or grading on the Property. E. This special use is contingent upon the Village of Buffalo Grove and T— Mobile . Central LLC entering into a lease concerning the proposed telecommunications facility. 'In ithe event that a lease is not executed, the Village may, in its. sole :discretion void ` the special use granted by this Ordinance. Section 4: This Ordinance: shall be' in full force and effect on, and after its passage and approval. This Ordinance shall not be- codified: AYES: 6 Itraimari Glover,' Trilling; Stone; Sussman NAYS: 0 - None. ABSENT: ' 0 None PASSED: 17, 2010 APPROVED: 'May 17, 2010 ATTEST: ) APPROVED: illage Clerk LLIOTT HART , Village President This document was prepared by: Robert E. Pfeil, Village Planner and William G. Raysa, Village Attorney Village of Buffalo Grove 50 Raupp Boulevard Buffalo Grove, IL 60089 E EXHIBIT A Legal Description T —Mobile telecommunications facility Buffalo Grove Golf Course . :48 Rau : a pp: Boulevard SUBJECT PROPERTY LEGAL DESCRIPTION: THAT .FART OF VILLAGE CAMPUS?:SUBDIVISION BEING A SUBDIVISION IN THE SOUTHEAST QUARTER OF SECTION 32, TOWNSHIP 42 NORTH, RANGE 11 EAST OF THE THIRD PRINCIPAL MERIDIAN IN LAKE COUNTY AND IN THE NORTHEAST QUARTER., OF SECTION 5, TOWNSHIP.42 NORTH;.RANGE:.11 EAST,OF THE THIRD PRINCIPAL MERIDIAN: COMMENCING AT THE SOUTHWEST CORNER OF SAID VILLAGE CAMPUS SUBDIVISION; THENCE: NORTH 34 DEGRESS 20 MINUTES 09 SECONDS WEST ALONG :. THE WESTERLY LINE OF SAID SUBDIVISION, 262.35 FEET; THENCE NORTH 55 DEGREES 40 MINUTES 02 SECONDSEAST 246:85' FEET TO THE POINT BEGINNING; THENCE CONTINUING NORTH 55 DEGREES 40 MINUTES 02 SECONDS EAST, 25.67 FEET; THENCE SOUTH 34 DEGREES 19 MINUTES 58 SECONDS EAST, 13.00 FEET; THENCE t SOUTH 55 DEGREES 40 MINUTES 02 SECONDS WEST, 25.67 FEET; THENCE NORTH 34 DEGREES 19 MINUTES 58 SECONDS WEST, 13.00 FEET TO THE POINT OF BEGINNING, CONTAINING 334.00 SQUARE FEET, MORE OR LESS, ALL IN COOK COUNTY, ILLINOIS. Location Map: 48 Ra-^u"*,p Blvd Village Bar &Grill 59'-6" 25'- \34' -4"� Fu re `c Gr nd Eq i menu 34' -0" Proposed T- Mobile Tower -\ Z,� - 2 "�aJQ�a <o �0 0 J�aA� o�Q o y2 G�J b 10' -0" Screen gate for garbage dumpster area �Ja O�avQ�a�� h ONO' / \ �O LAKE—COOK 4n� mmh 20 0 80 120 30 10 30 90 Z �\ <�� ��G G� YD G�